9
LockNode will restart.
9
LockNode is restarted.
Restarting LockNodes via power connection
Your LockNodes are reset and restart when you disconnect the power (or
remove the LNI), wait half a minute and reconnect (or reinstall the LNI).
After the restart the LockNodes beep four times.
5.5.3 Reprogram or replace the device
If you have problems with a device, try the following before replacing it:
Reprogram the device
Reset and re-program the device (see
)
Reprogram the device
The flash symbol in the overview indicates a problem with your device. Try
to reprogram the configuration on the same device. To do this, perform the
replacement procedure as described (see
and
) with the same IP address or chip ID of the device you
want to reprogram. You transfer the configuration of the device you want
to replace to the device that has that chip ID. If this is the same Chip ID,
then the configuration is reprogrammed on the device.
Replace device
You can replace devices in WaveNet if a device is no longer to be used for
the following reasons, for example:
Replacement
Vandalism
Theft