NOTE
You must not strike the thumb turns when installing the cylinder. Do not al-
low the cylinder to come into contact with oil, paint or acids.
6.3.2.3 Fastening the inside thumb-turn
Screw the inside thumb-turn onto the thread until it locks into place as it
comes up against the cam in the lock. Pull on the inside thumb-turn, or
push on the inside thumb-turn of a freely rotating AP cylinder, until it locks
into position. Fasten the threaded pin tightly using the Allen key.
6.3.2.4 Functional test
To verify that the AP2 cylinder functions correctly in an anti-panic lock,
you must check that the cam moves easily and that the door opens
correctly using the procedure described below.
Carry out the functional test in the direction of escape.
You must carry out a functional test whenever the cylinder or the
fastening screw is repositioned.
You will need an authorised identification medium to carry out the
functional test.
Withdraw the dead bolt before the functional test.
U section:
No restore force on the cam
R section:
Restore force section towards U section
SmartIntego
Locking cylinder
(Manual)
6. Installation guide for 'SmartIntego'
21 / 44