5.5 AP version
A cylinder with an anti-panic function must be fitted to all doors where the
lock's panic function may be adversely affected by the position of the cam.
This version contains an integrated spring mechanism which places the
locking cam in a non-critical position, meaning a panic lock's panic function
cannot be blocked.
In contrast to all other cylinders, the .AP type cylinder is fitted the other way
round with the thumb-turn containing the battery and the electronics
module installed on the outside (see diagram).
Unlike the standard anti-panic cylinder (AP), the inside thumb-turn of
which is permanently engaged, the inside thumb-turn for the freely-
rotating AP version (AP.FD) is disengaged mechanically and cannot be
engaged with an identification medium.
1. Inside thumb-turn
2. Recessed grip ring
3. Battery replacement key
4. Outside thumb-turn
The following aspects should be taken into consideration for doors along
rescue routes which have been installed after April 1, 2003 (exit devices as
per DIN EN 179 or DIN EN 1125): All SI-Locking Cylinder models may be used
for all exit devices where their approval states that the SI-Locking Cylinder
has no impact on the lock's function. The SI-Locking Cylinder type .AP
SmartIntego