132
ENG
Next, on selecting Login we go to a screen for entering the
password. The preset one is
1, 1.2, 3 and 4
(the first 4
buttons from left to right / up and down in order).
Once the password has been entered, the installer start screen
will appear with new system tools.
Also, provided we are in installer mode, a
gear
icon will light
up.
4.1.1 Checking the Installation, Test Screen
Test
Test is a method for acknowledging the devices connected
and checking their communication with the Touch
LightKeypand screen.
As we can see in the example, the list gives us the connected
modules, in order, with their name and address. If the
communication is not good or there is no communication at all
the channel is highlighted in red.
IMPORTANT
The protocol converter modules (DMX-PWM and DMX-DALI) will not
be identified using TEST but the other devices will be identified and
checked. The converters will only appear if they have been previously
registered in the Touch LightManager console.