User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-99/141
◦
in
Low Limit
parameter write
-50000 1/sec.
,
◦
in
High Limit
parameter write
50000 1/sec.
,
◦
Counting mode
parameter set as
with direction input
,
◦
Filter
parameter set as
disable
,
◦
Zero time
parameter set as
0.1 sec.
,
◦
press
Totalizer
button,
–
Reset mode
parameter set as
from log. channel
,
–
Reset source
parameter set as
Logical channel 3
,
–
Strobe mode
parameter set as
from log. channel
,
–
Strobe source
parameter set as
Logical channel 4
,
–
Counting direction
parameter set as
from log. channel
,
–
Direction source
parameter set as
Logical channel 5
,
•
Scaling
parameter set as
linear
,
•
press
Configure scaling
button,
◦
in
Output unit
parameter write
dm
3
/s
,
◦
in
Input value
in
Point 1
label write
0 1/sec.
,
◦
in
Output value
in
Point 1
label write
0 dm
3
/s
,
◦
in
Input value
in
Point 2
label write
512 1/sec.
,
◦
in
Output value
in
Point 2
label write
1 dm
3
/s
,
•
Format
parameter set as
numeric
,
•
Precision
parameter set as
0.00
,
•
in
Graph low
parameter write 0
dm
3
/s
,
•
in
Graph high
parameter write
100 dm
3
/s
,
To display Total flow:
–
using the arrows in the top navigation bar, select
logical channel 2
,
•
in
Name
parameter write
Total flow
,
•
Mode
parameter set as
Data from other channel
,
•
Source
parameter set as
Log.ch.1:”Measurement”
,
•
Quantity
parameter set as
totalizer
,
•
Precision
parameter set as
0.00
,
•
in
Graph low
parameter write
0 dm
3
,
•
in
Graph high
parameter write
1000 dm
3
,
–
using the arrows in the top navigation bar, select
logical channel 3
,
•
in
Name
parameter write
Reset
,
•
Mode
parameter set as
Set point value
,
•
Edit button
parameter set as
enabled
,
•
Format
parameter set as
binary
,
–
using the arrows in the top navigation bar, select
logical channel 4
,
•
in
Name
parameter write
Strobe
,
•
Mode
parameter set as
Set point value
,
•
Edit button
parameter set as
enabled
,
•
Format
parameter set as
binary
,
–
using the arrows in the top navigation bar, select
logical channel 5
,
•
in
Name
parameter write
Direction
,
•
Mode
parameter set as
Set point value
,
•
Edit button
parameter set as
enabled
,
•
Format
parameter set as
binary
,
–
all other parameter should be set on default settings,
136