background image

Model 3963C

Preplumbed Sewage 

Pump System

Installation, Operation, & Parts Manual

Safety Information

Carefully read and follow all safety instructions in this manual 

or on pump.

 indicates a hazard which, if not avoided, 

will

 

result in death or serious injury.

 indicates a hazard which, if not avoided, 

could

 

result in death or serious injury.

 indicates a hazard which, if not avoided, 

could

 

result in minor or moderate injury.

NOTICE

 addresses practices not related to personal injury.

1.  Read these rules and instructions carefully. Failure to 

follow them could cause serious bodily injury and/or 

property damage.

2.  Check your local codes before installing. You must comply 

with their rules.

 

 Hazardous voltage. Can shock, burn, or 

kill. During operation the pump is in water.To avoid fatal 

shocks, proceed as follows if pump needs servicing:

3A.  Disconnect power to outlet box before unplugging pump. 
3B.  Take extreme care when changing fuses. Do not stand in 

water or put your finger in the fuse socket.

3C.  Do not modify the cord and plug. When using the cord 

and plug, plug into a grounded outlet only. When wiring 

to a system control, connect the pump ground lead to the 

system ground.

4.  Do not run the pump dry. Dry running can overheat the 

pump, (causing burns to anyone handling it) and will void 

the warranty. 

5.  The pump normally runs hot. To avoid burns when 

servicing pump, allow it to cool for 20 minutes after shut-

down before handling it.

6.  The pump is permanently lubricated. No oiling or 

greasing is required in normal operation. for overhaul, see 

instructions under “Service”.

7.  Vent sewage or septic tank according to local codes.
8.  Do not install the basin or pump in any location classified 

as hazardous by the United States National Electrical 

Code (NEC), or by the Canadian Electrical Code (CEC), 

where applicable.

Pump Specifications

Power Supply Required ................................................... 115V
Individual Branch Circuit Required ............................20 Amps
Maximum Liquid Temperature ............................. 130°F(55°C)*
Discharge Adapter ........................................................ 2

 NPT

Description

The Simer Sewage Pump System, Model Number 3963C is 

ideal for basement installations, pumping below-grade toilets, 

and laundry facilities. It includes a submersible sewage pump, 

a premium heavy duty structural foam, corrosion resistant 

sump/sewage basin and lid, and a check valve for easy 

installation. 
This submersible pump is designed for effluent and wastewater 

removal, sump drainage, dewatering and flood control. 

The pump has built in thermal overload protection and 

an automatic reset. The mechanical seal and ball bearings 

on the motor shaft are permanently lubricated. Stainless 

steel hardware and a heavy duty lift out ring allow for easy 

disassembly after extended use.
The basin is used for residential, commercial, and industrial 

collection of sewage, effluent drainage and seepage water. The 

basin cover kit includes an inlet hub, a gas tight cover, cord 

seals, gaskets, and hardware. No special tools or sealants are 

required.

NOTICE:

 This unit is not designed for applications involving salt 

water or brine! Use with salt water or brine will void warranty.

© 2011 

 

SIM538 (Rev. 4/20/11)

 

 

 

 

Individual 

 

Switch Setting in inches (mm) 

Discharge

 

 Model 

Motor 

Motor Full 

Branch Circuit 

Cord Length 

       

 

Adapter

 

 Number 

HP 

Load Amps 

Required (Amps) 

in ft. (m) 

On       

Off 

Size

 

3963 

1/2 

13.0 

20 

10 (3.0) 

16 (406) 

7 (178) 

2”

Pump, Motor, Switch, & Cord Specifications

293 Wright Street, Delavan, WI 53115
Phone: 1-800-468-7867
Fax: 1-800-390-5351
Web Site: SimerPump.com

Содержание 3963C

Страница 1: ...cording to local codes 8 Do not install the basin or pump in any location classified as hazardous by the United States National Electrical Code NEC or by the Canadian Electrical Code CEC where applica...

Страница 2: ...l codes that apply Explosion hazard Improper ventilation of sewer gases can result in leakage of methane sewer gas and a possible explosion of fumes resulting in severe injury or death Vent basin acco...

Страница 3: ...rical power to the pump and the control switch Do not lift the pump by the power cord See the Cord Lift Warning below NOTICE Always wear gloves when handling the pump for service or maintenance NOTICE...

Страница 4: ...Bolt 8 7 Washer 8 8 Sewage Basin Cover 1 PW73 48 9 Gasket Tape Cover 1 10 Sewage Basin 1 PW73 46 11 Inlet Hub Snap In 1 12 Sewage Pump 1 3963 13 Discharge Pipe 1 U78 996P Hardware Package 1 Incl Key N...

Страница 5: ...t hole in the pump discharge is not plugged 5 Check for blockage in pump inlet impeller check valve or discharge pipe 6 Disconnect the pump from the power source for a minimum of 30 minutes to allow t...

Страница 6: ...handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Tw...

Страница 7: ...t pas n cessaire de la huiler ni de la graisser Si la pompe doit tre r vis e se reporter aux instructions figurant sous la rubrique Entretien 7 Pr voir une mise l air libre ad quate du r servoir des e...

Страница 8: ...phase indiqu es sur la plaque signal tique du moteur de la pompe correspondent exactement au courant d alimentation Installer la pompe conform ment aux codes de l lectricit en vigueur Risque d explos...

Страница 9: ...lifi Aucune pi ce de cette pompe n est r parable par une personne non qualifi e Apr s avoir enlev le couvercle du bassin et d branch toute la tuyauterie de refoulement n cessaire sortir la pompe du ba...

Страница 10: ...D signation des pi ces Qt 3963C 1 Clapet de non retour en PVC de 2 po battant 1 PW73 49 2 Bague d tanch it en caoutchouc pour le passage du tuyau de refoulement 2 po 1 3 Joint torique taille droite 2...

Страница 11: ...e mise l air libre antibouchon d air du refoulement de la pompe n est pas bouch 5 S assurer que l admission de la pompe l impulseur le clapet de non retour ou le tuyau de refoulement ne sont pas bouch...

Страница 12: ...la pompe des fins de garantie retourner l tiquette figurant sur le cordon de la pompe et l original du re u au d taillant Mettre la pompe au rebut conform ment la r glementation locale Exceptions la...

Страница 13: ...grasa bajo una operaci n normal Consulte las instrucciones en la secci n de Servicio para la puesta a punto 7 Ventile el tanque s ptico o de aguas residuales conforme con los c digos locales 8 No inst...

Страница 14: ...rada Instale la bomba conforme con todos los c digos el ctricos que correspondan Peligro de explosi n Una ventilaci n inadecuada de los gases del sumidero puede resultar en fugas de gas metano del sum...

Страница 15: ...l capacitado La bomba no contiene piezas de consumo que se puedan reparar Despu s de sacar la cubierta del dep sito y la tuber a de descarga necesaria levante y saque la bomba del dep sito Coloque la...

Страница 16: ...e No Descripci n de la pieza Cant 3963C 1 V lvula de retenci n PVC oscilante de 2 1 PW73 49 2 Aro de refuerzo de descarga 2 1 3 Aro t rico de corte cuadrado 2 4 Aro de refuerzo del cord n 1 5 Aro de r...

Страница 17: ...carga de la bomba no est obturado 5 Verifique que la admisi n de la bomba el impulsor la v lvula de retenci n o la tuber a de descarga no est n bloqueados 6 Desconecte la bomba de la fuente de corrien...

Страница 18: ...ci n Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garant a devuelva la etiqueta del cord n de la bomba y el recibo de compra original a la tienda...

Страница 19: ...Para refacciones o asistencia llame a Simer Servicios al Cliente al 1 800 468 7867 19...

Страница 20: ......

Отзывы: