41
tage of CO
2
, the mass flow of smoke
at nominal load, the temperature of
the smoke, the roughness of the inter-
nal wall, and the effect of gravity on
the draught pressure, which must
take into account the external tempe-
rature and the altitude.
2.6
ELECTRICAL CONNECTION
The boiler is supplied with an electric
cable. Should this require replace-
ment, it must be purchased exclusi-
vely from SIME. The electric power
supply to the boiler must be 230V -
50Hz single-phase through a fused
main switch, with at least 3 mm spa-
cing between contacts. The room stat
must be class II as specified by stan-
dard EN 60730.1 (clean contact).
NOTE: Device must be connected to an
efficient earthing system. SIME decli-
nes all responsibility for injury or dama-
ge to persons, animals or things, resul-
ting from the failure to provide for pro-
per earthing of the appliance. Always
turn off the power supply before doing
any work on the electrical panel.
Fig. 5
KEY
IG
Main switch
TC
Regulation stat with double contact
EA
Ignition electrode
EV2
Gas valve coil
EV1
Gas valve coil
TA
Room stat
R
Lock out reset button
B
Coil assembly
ER
Sensing electrode
TS
Safety stat
A
FM 11 control box
TF
Smoke stat
FA
EMC filter
NOTA: The room stat must be connec-
ted to the terminals 3-4.
Fig. 4
Tetto piano
0,50 m
0,50 m
Volume
tecnico
> 5 m
≤
5m
Colmo
> 1,50 m
≤
1,50 m
Zona di reflusso
1
,50 m
2 m min.
0,50 m
oltr
e il colmo
45
°
Tetto a 45
°
Colmo
> 1,30 m
≤
1,30 m
Zona di reflusso
0,80 m
1
,20 m min.
0,50 m
oltr
e il colmo
30
°
Tetto a 30
°
Flat roof
30° roof
45° roof