Programme for hot-water service
(with storage capacity boiler unit)
Select the days that correspond with the heating phase.
1= Monday, ... 7 = Sunday/8 = hot-water service programme
Start of phase 1: Start of first comfort period.
End phase 1: End of first comfort period.
Start phase 2: Start of second comfort period.
End phase 2: End of second comfort period.
Start phase 3: Start of third comfort period.
End phase 3: End of third comfort period.
Copying of the daily programme
By pressing this key it is possible to repeat the current heating programme
for the
next day
.
By pressing this key it is possible to repeat the current heating programme
for the
previous day
.
As a confirmation the following day is displayed.
4
5
6
7
8
9
10
1 1
With the Logic Remote Control it is possible to manage the temperature of boiler unit on two
levels (a comfort level and one at reduced temperature) in accordance with the programme
chosen with parameter 62 (load hot-water service). To have access to the parameter press
the
and
keys for at least 5 seconds and then go along the entered lines with the
key until parameter 62 is reached. At this point four different programmes may be selected
with
o
keys, with the following characteristics:
0
= 24 hours/ day - Hot water always available at the temperature set in parameter 3.
1
= standard - Hot water according to the daily heating programme. In the comfort periods
of the heating the temperature of the boiler unit is regulated at the value set via para-
meter 61.
2
= sservice suspended.
3
= second daily programme (8) - Everyday of the week the temperature of the hot-water ser-
vice is set according to programme B. In this case the programming is one for all the days
of the week and three periods of time are available. In the periods of time set, the tem-
perature of the boiler unit is controlled via the temperature setting of parameter 61.
Start phase 1: Start time of first comfort period.
End phase 1: End time of first comfort period
Start phase 2: Start time of second comfort period.
End phase 2: End time of second comfort period.
Start phase 3: Start time of third comfort period.
End phase 3: End time of third comfort period.
5
6
7
8
9
10
–
Heating/hot-water
service programme
With the heating programme it is possible to set the switching times of the temperature for a
period of a week. The weekly programme consists of 7 daily programmes. One daily program-
me allows 3 phases of heating. Each phase is defined by a starting time and a finishing time.
The n. 8 daily programme is for the hot-water service (if storage unit connected). If a phase is
not required, the same starting and finishing time may be entered.