2.8

LOGICA REMOTE CONTROL

USED WITH SINGLE BOILERS.

All the boiler's functions can be managed

by a optional digital multifunctional device

code 8092204 for the remote of the boi-

ler itself and for regulating room climatic

conditions with an operational reserve of

12 hours.

The heating circuit is controlled by the room

temperature sensor built-in the equipment

or by the atmospheric conditions, with or

without environmental inflow, if the boiler is

connected to an external sensor.

Characteristics:

– Ergonomic control unit divided according

to function (control levels)).

– Clear division of basic functions:

operating regime, correction of set

value and presence button are directly

accessible;

Dif fer ent r eal curr ent values ar e

accessible through the "info" button;

other functions can be programmed

after the cover has been opened;

special service level with protected

access;

– Each setting or modification is displayed

and confirmed.

– Tome setting (special line for changing

BST/CET).

– Heating programme with max. 3 heating

periods per day, individually selectable.

– Copy function for easy transfer of hea-

ting programme to the next or pre-

vious day.

– Holiday programme: the programme is

interrupted for the holiday period and

automatically restar ted on returning

home.

– Option to return the heating program to

default values.

– Programming lock (child safety).

Functions:

– Delivery temperature control guided by

the atmospheric conditions, taking into

account the dynamics of the building.

– Delivery temperature control guided by

atmospheric conditions with influence of

ambient temperature.

– Ambient temperature control only.

– Adjustable influence of ambient tempera-

ture shift .

– Switch-on and switch-off optimisation.

– Rapid lowering.

– ECO functions (daily heating limiter, auto-

matic summer/winter switch-over).

– Controllable maximum delivery tempera-

ture limit (specifically for floor plants).

– Limitation of increase in pre-set delivery

temperature.

– Anti-freeze protection for buildings.

– Hourly programming of the tank unit

temperature on two levels: comfort and

reduced.

– Domestic hot water control with nominal

value requirement and enable.

– Connection to room sensor or switching

of operating regime through the telepho-

ne sys t em wit h ext ernal cont act or

through a window contact.

– Anti-bacterial.

2.8.1

Installation

The unit must be installed in the main living

room. For installation, follow the assembly

instructions inserted in the package. At this

point, with the selector knob on (

), the

installer can adjust the basic parameters set-

tings according to the individual needs (point

2.8.2). 

The radiators in the room that the Logica is

fitted must not have thermostatic valves.

2.8.2

Installation settings

The settings for the basic operating para-

meters for individual needs are shown in

the instruction leaflet supplied with the

"Logica Remote Control" and in the section

reserved for the user in this manual.

For further adjustments which can be car-

ried out by the installer, the "Logica Remote

Control" offers a level of service and para-

meterising which can only be accessed

through a special combination of buttons.

To activate this level of service or parame-

terising press buttons

and

least 5

seconds. 

This will activate the parameterising level.

Then use the same arrow buttons to select

the individual input lines and adjust the

values with

or

.

Antifreeze protection 

"Pre-set ambient 

temperature value"

Summer/Winter switch-over 

temperature

Type of control:

0 = with ambient influence

1 = without ambient influence

Influence of ambient temperature

Heating takes place up to this pre-set value if the plant is activated in standby

(e.g. holidays). 

In this way, the building antifreeze function is active, preventing an excessive

lowering of the ambient.

This parameter regulates the temperature of the automatic summer/win-

ter switch-over.

This parameter de-activates the ambient influence and as a result all the

optimisations and adaptations. 

If a valid external temperature is not transmitted , the controller switches to

the  pure ambient control guide variable.

If the ambient controller is used only as a remote control (placed in the refe-

rence room and without an external sensor connected), the value must be

set at 0 (zero). 

If the change in ambient temperature from the pre-set value remains high

during the entire day, the influence must be increased. If the ambient tem-

perature is around the pre-set value (control oscillation), the influence must

be reduced. 

Note: If the ambient temperature influence constant is set at 0, the adap-

tation of the heating curve is deactivated. In this case, parameter 57 will

have no effect at all.

54

HEATING CIRCUIT SETTINGS

52

53

51

Содержание PLANET DEWY 100

Страница 1: ...ro perly installed Make sure that any shutoff valves are open Make sure that the system is charged with water and is thoroughly vented Check that the circulating pump is not locked Purge the system bl...

Страница 2: ...Filling system G 1 2 UNI ISO 228 1 R3 Tank return G 1 UNI ISO 228 1 S3 Condensation outlet 25 CA Inlet 80 CS Outlet 80 ATTENTION the boiler is supplied as Class B device To install the boiler as Class...

Страница 3: ...panel 16 Safety valve 4 BAR 1 3 2 PLANET DEWY 100 BFR 1 2 3 4 5 6 7 8 18 13 9 10 11 14 17 15 Fig 2 a KEY 1 Gas valve 2 Condensation drain siphon 3 Fan 4 Air pressure switch 5 Ignition electrode 6 Det...

Страница 4: ...es temperature minimum 50 30 C C 32 32 Smokes flow kg h 97 166 CO2 maximum minimum G20 9 0 9 0 9 0 9 0 CO2 maximum minimum G31 10 0 10 0 10 0 10 0 Maximum pressure exhaust manifold output Pa 110 170 A...

Страница 5: ...trol unit code 8096301 supplied by Sime upon request a maximum of four boilers can be controlled The control unit kit is supplied with assembly and use instructions 2 INSTALLATION 45 146 R3 500 865 58...

Страница 6: ...poor gas valve operation or failure of any gas valve safety feature it is advisable to fit a suitable filter on the gas supply pipe 2 5 FILLING THE SYSTEM Cold system filling pressure must be 1 bar Th...

Страница 7: ...the internal section of the gaskets with silicon products and generally avoid the use of oils and greases TABLE OF LOAD LOSSES OF ACCESSORIES Fig 4 a KEY 1 80 curve 90 MF 6 pcs code 8077450 2 a 80 ext...

Страница 8: ...orizontal terminals must be LEVEL WARNING In the versions 60 BFR he insertion of a 90 additional curve reduces the available length by 2 meters end the insertion of a 45 additional curve reduces the a...

Страница 9: ...m use cables of sec tion 0 25 mm2 for longer lengths up to 50 m use cables of section 0 5 mm2 To gain access to boiler connector 3 remo ve the control panel cover and connect the external temperature...

Страница 10: ...mer NOTE Connect the room thermostat TA to terminals 5 6 after removing the bridge Fan control board SV MAX and MIN trimmers are sealed and must never be tampered with CONNECTOR SPARE PART CODES J2 co...

Страница 11: ...CR Remote Control Logic optional SV Fan board TF Exhaust thermostat PA Air pressure switch SB Boiler probe PB Boiler pump TRA Ignition transformer NOTE Connect the room thermostat TA to terminals 5 6...

Страница 12: ...ump PI System pump R R1 R2 Relay CR CR1 CR2 Relay contact TA Room thermostat VR Non return valve M C H flow R C H return Note The relay R disconnects the heating pump when the requirements of both ser...

Страница 13: ...must be installed in the main living room For installation follow the assembly instructions inserted in the package At this point with the selector knob on the installer can adjust the basic paramete...

Страница 14: ...e imposed value With the activation of the adaptation the pre set value transmitted to the boiler regulator is adapted to the effective heat need The adaptation functions with both the atmospheric gui...

Страница 15: ...ssible to switch over to reduced pre set value of the antifreeze ambient temperature short circuit 0 0 0 or interruption _ _ _ The display shows the current status of the external contact 64 Operating...

Страница 16: ...ting pressure The addition of a bridge will cancel both the programmed technical delay and the minimum pressure operating period at ignition In this case the time between shut down and the next igniti...

Страница 17: ...No flame detection At ignition the electrode continues to spark even though the burner is on After 10 sec it stops sparking the burner turns off and the block led turns on This may be due to a faulty...

Страница 18: ...Y 1 Gas valve 2 Condensation drain siphon 3 Boiler pump not supplied 4 Fan 5 Heating probe SM 6 Safety thermostat 95 C 7 Exhaust thermostat 8 Primary exchanger 9 Diaphragm 10 Differential pressure swi...

Страница 19: ...AR safety valve 18 Non return valve not supplied 19 Hydraulic compensator supplied in the kit 20 Drain tap not supplied 21 Expansion vessel 8 liter supplied in the kit 22 Air relief valve not supplied...

Страница 20: ...n 0 2 from the table values the following corrections must be made To correct CO2 to the MIN power use the OFF SET screw 2 Drawing 6 To correct CO2 to the MAX power use the shutter 1 Drawing 6 Drawing...

Страница 21: ...he spe cial opening fig 20 4 4 1 Chimney sweep function To check single module combustion rotate the selector to position until the yellow led starts to blink fig 21 At this time the module will start...

Страница 22: ...d the yel low heating led turns on simulta neously If the water return tempera ture is lower than about 55 C com bustion product condensates further increasing heat exchange efficiency GAS CONVERSION...

Страница 23: ...l the green 1 bar led turns on If all leds are off request an authorised engineer Safety exhaust thermostat triggered fig 5 If the safety exhaust thermostat triggers the red 35 C led blinks To attempt...

Страница 24: ...n 5 Operating mode button availability 6 Cover with instruction compartment 7 Temperature knob 8 Presence button Fig 8 KEY 1 Display time 2 Heating programme 3 Unit C 4 Presence button display 5 Exter...

Страница 25: ...to function independently of the display Day hour room temperature External temperature Hot water service temperature Only with outside sensor fitted Info key reference key grey colour The operating...

Страница 26: ...service temperature parameter press the and keys at the same time for at least 5 seconds and then go along the entered lines with the key until parameter 61 is reached Regulate the value with and Bef...

Страница 27: ...ter 3 1 standard Hot water according to the daily heating programme In the comfort periods of the heating the temperature of the boiler unit is regulated at the value set via para meter 61 2 sservice...

Страница 28: ...Setting the time To set the current day of the week 1 Monday 7 Sunday To set the current hour To set the current minute Once the hour is completed the setting of the hour changes 12 13 14 With and ke...

Отзывы: