BOILER IGNITION
(fig. 1)
Open the gas valve, lower the control panel
cover and activate the boiler by rotating the
selector knob to the summer positio (
).
The lighting-up of the green led (
)
will indicate that the apparatus is switched-
on and ready.
–With the rotary switch in the summer
position (
) the boiler will star t-up
upon demand for domestic hot water,
and run at full power to reach the selec-
ted temperature.
The gas feeding pressure will then auto-
matically vary to ensure that the requi-
red temperature is kept constant.
– With the rotary switch in the winter
position (
) once the boiler has rea-
ched the value set on the heating poten-
tiometer, it will star t to modulate in
automatically in order to supply the
required power output to the system.
The operation of the boiler will be stop-
ped through the inter vention of the
timer-thermostat or “Logica Remote Con-
trol”.
TEMPERATURES ADJUSTMENT
(fig. 2)
–The D.H.W. temperature can be adju-
sted by turning the knob of the D.H.W.
potentiometer (
).
When there is a demand for hot water
the yellow led (
) lights-up.
When model
“25 BFT TS”
is connected
with a
“BT100”
tank unit, when there is
no request for heating or D.H.W. produc-
tion (the leds
and
are off), the
tank unit maintenance temperature will
appear on the red led scale 35÷80°C
– The C.H. temperature can be adjusted
by turning the knob of the C.H. potentio-
meter (
). The set temperature is indi-
c a t e d o n t h e r e d l e d s c a l e f r o m
35÷80° C and the yellow heating led
lights up at the same time (
).
To ensure optimal boiler efficiency at all
times, we recommend not to drop below
a minimum working t emperatur e of
50°C.
TURNING THE BOILER OFF
(fig. 1)
To turn the boiler off place the selector
knob on the
OFF
position. If the boiler is
not going to be used for a lengthy
WARNINGS
–In case of fault and/or incorrect equipment operation, deactivate it, without making any repairs or taking
any direct action. Contact the nearest Authorised Technical Staff.
–The installation of the boiler and any servicing or maintenance job must be carried out by qualified person-
nel. Under no circumstances, the devices sealed by the manufacturer can be tampered with.
–It is absolutely prohibited to block the intake grilles and the aeration opening of the room where the equip-
ment is installed.
LIGHTING AND OPERATION
R
E
M
O
T
E
C O N T R O L
R
APRE
SPIA VERDE
Fig. 1
GREEN LED
OPEN
FOR USER
Содержание PLANET 25 BFT TS
Страница 1: ...IT ES PT GB RO RUS CERTIFICAZIONE DEL SISTEMA DI QUALITA AZIENDALE Planet...
Страница 2: ......
Страница 72: ...70 IT ES PT GB RO RUS...
Страница 106: ...104 IT ES PT GB RO RUS...
Страница 140: ...138 IT ES PT GB RO RUS...
Страница 208: ...206 IT ES PT GB RO RUS...
Страница 209: ......
Страница 210: ......
Страница 211: ......
Страница 212: ...Fonderie Sime S p A Via Garbo 27 37045 Legnago Vr Tel 39 0442 631111 Fax 39 0442 631292 www sime it...