74
1.3
TECHNICAL FEATURES
(1) Flow calculated with a fixed temperature on the D.H.W. potentiometer of 60 °C for a maximum period of 10 minutes
(2) The gas consumptions refers to the calorific value at standard conditions at 15°C - 1013 mbar
(3) Differential measure between the pressure upstream of the gas valve and the depression in the sealed room
25/60 OF
25/60 BF
30/60 BF
Heat output
Nominal
kW
8,4 ÷ 23,2
9,3 ÷ 25,0
11,6 ÷ 29,5
kcal/h
7.200 ÷ 20.000
8.000 ÷ 21.500
10.000 ÷ 25.400
Minimum
kW
8,4
9,3
11,6
kcal/h
7.200
8.000
10.000
D.H.W. heat output
Nominal
kW
23,2
25,0
29,5
Heat input
Nominal
kW
10,8 ÷ 25,8
10,8 ÷ 26,7
13,5 ÷ 31,6
Minimum
kW
10,8
10,8
13,5
Water content
l
4
4
5
Adsorbed power consumption
W
105
165
180
Electrical protection grade
IP X4D
IP X4D
IP X4D
Maximum water head
bar
3
3
3
Maximum temperature
°C
85
85
85
Expansion vessel
Water content/Preloading pressure
l/bar
8/1
8/1
8/1
C.H. setting range
°C
40÷80
40÷80
40÷80
D.H.W. setting range
°C
10÷60
10÷60
10÷60
D.H.W. production
Tank capacity
l
60
60
60
Continuous D.H.W. flow rate at
∆
t 30°C
l/h
684
684
774
Specific D.H.W. flow rate EN 625
(1)
l/min
14,5
14,5
16,1
D.H.W. maximum water head
bar
7
7
7
Recovery time from 25°C to 55°C
min
4’ 30”
4’ 30”
4’
D.H.W. expansion vessel
l
2,5
2,5
2,5
Smoke temperature
°C
110
123
123
Smoke flow
gr/s
21,0
17,0
20,0
Category
II
2H3+
II
2H3+
II
2H3+
Type
B
11BS
C
12
- C
32
- C
42
- C
52
C
12
- C
32
- C
42
- C
52
Weight
kg
74
82
82
Main gas nozzles
Quantity
n°
13
13
15
Methane
ø mm
1,30
1,30
1,30
G30 - G31
ø mm
0,75
0,76
0,76
Gas flow
(2)
Methane
m
3
st/h
2,73
2,83
3,34
Butane (G30)
kg/h
1,99
2,06
2,44
Propane (G31)
kg/h
1,96
2,03
2,40
Gas burner pressure
Methane
mbar
1,8÷9,7
1,9÷10,8
(3)
1,7÷11,3
(3)
Butane (G30)
mbar
4,7÷27,4
4,7÷28,4
(3)
4,7÷28,1
(3)
Propane (G31)
mbar
6,3÷35,3
4,7÷35,3
(3)
4,7÷35,9
(3)
Gas supply pressure
Methane
mbar
20
20
20
Butane (G30)
mbar
30
30
30
Propane (G31)
mbar
37
37
37
Содержание Format 25/60