SensorIQEasy_UM_9752023110_NL_D_GB_V2_0
56
6.3 Selecting mounting distance Sensor (expert mode)
For an accurate measurement the mounting distance whereupon the Sensor is mounted in the
parameters setting needs to be entered. By default, this is set to 50mm. If the value of this
parameter departs from the actual mounting distance the measure value displayed will not
correspond with the actual value.
Select the Sensor
Now the
Information
tab of the sensor is displayed.
Indicate that you want to change settings by choosing the settings button
The
information
Tab consists of several pages. With the
buttons you can scroll through
the various pages.
Find the parameter
Mounting distance sensor
and select
Enter the mounting distance.
Confirm the value entered using
. When the sensor is used at short distance and the
Mounting distance
parameter is set to a value less than 50 mm, the Web voltage parameters
are displayed with extra accuracy to 3 decimal places.
6.4 Set the warning set point (expert mode)
The Sensor IQ Easy bar will generate a warning if the average measured value reaches the
Warning set point
(during
warning/error delay
see 6.6 )
.
This value is set to 5kV by default, but it can be easily adjusted:
- [
(n)x
“
Clean bar warning level
”
slide slider or use
to go to the desired value and confirm with
].