5. Register Map
The register map is divided into multiple pages where each page has 256 addressable registers. Page 0 contains
frequently accessible register such as alarm status, resets, device identification, etc. Other pages contain registers
that need less frequent access such as frequency configuration, and general device settings. A high level map of
the registers is shown in “5.2. High-Level Register Map” . Refer to the Si5341/40 Family Reference Manual for a
complete list of registers descriptions and settings.
5.1. Addressing Scheme
The device registers are accessible using a 16-bit address which consists of an 8-bit page a 8-bit register
address. By default the page address is set to 0x00. Changing to another page is accomplished by writing to the
‘Set Page Address’ byte located at address 0x01 of each page.
5.2. High-Level Register Map
Table 16. High-Level Register Map
16-Bit Address
Content
8-bit Page
Address
8-bit Register
Address Range
00
00
Revision IDs
01
Set Page Address
02–0A
Device IDs
0B–15
Alarm Status
17–1B
INTR Masks
1C
Reset controls
2C–E1
Alarm Configuration
E2–E4
NVM Controls
FE
Device Ready Status
01
01
Set Page Address
08–3A
Output Driver Controls
41–42
Output Driver Disable Masks
FE
Device Ready Status