![Silicon Graphics Origin 350 Скачать руководство пользователя страница 72](http://html.mh-extra.com/html/silicon-graphics/origin-350/origin-350_user-manual_1271649072.webp)
46
007-4566-001
1: Installation and Operation
Figure 1-25
Cabling a Base Compute Module to a System Expansion Compute Module
Figure 1-26 shows the cabling of the following server system modules (and other items)
to each other in a 39U rack:
•
SGIconsole (system console) to monitor and manage your system. (The LAN2 port
connects to the L2 controller’s Ethernet port with an RJ-45 twisted-pair cable.)
•
L2 controller. (Using an RJ-45 twisted-pair cable, the L2 controller’s L1 port
connects to the NUMAlink module’s L1 port.)
•
Two 4U PCI expansion modules. (Using a NUMAlink 3 cable, the NUMAlink port
of the top PCI expansion module connects to the NUMAlink module’s 2-B port.
Using another NUMAlink 3 cable, the NUMAlink port of the lower PCI expansion
module connects to the NUMAlink module’s 3-C port.
•
NUMAlink module. (Using a NUMAlink 3 cable, the NUMAlink module’s G-7 port
connects to the system expansion compute module’s NUMAlink port. Using
another NUMAlink 3 cable, the NUMAlink module’s F-6 port connects to the base
compute module’s NUMAlink port connector.
•
System expansion compute module.
•
Base compute module. (Using a SCSI cable, the SCSI port on the base compute
module connects to the TP900 module’s SCSI port.)
•
TP900 storage module.
Base compute module
System expansion compute module
XIO
NUMAlink
XIO
NUMAlink
Содержание Origin 350
Страница 1: ...SGI Origin 350 Server System User s Guide 007 4566 001 ...
Страница 3: ...007 4566 001 iii Record of Revision Version Description 001 June 2003 Original publication ...
Страница 4: ......
Страница 16: ......
Страница 26: ......
Страница 41: ...Installing a Rack 007 4566 001 15 Figure 1 5 Removing a Short Rack from the Shipping Crate Peg ...
Страница 50: ...24 007 4566 001 1 Installation and Operation Figure 1 11 Location of Table mounting Feet ...
Страница 90: ......
Страница 93: ...Physical Features 007 4566 001 67 Figure 2 1 Example of SGI Origin 350 Server Systems 17U rack 39U rack ...
Страница 132: ...106 007 4566 001 2 System Overview Figure 2 27 Front Views of Short and Tall Racks 17U rack 39U rack ...
Страница 158: ......
Страница 180: ......
Страница 204: ...178 007 4566 001 6 Installing and Removing Customer replaceable Units Figure 6 19 Installing a Disk Drive B A D C ...
Страница 206: ...180 007 4566 001 6 Installing and Removing Customer replaceable Units Figure 6 20 Removing a Disk Drive C A B D ...
Страница 211: ...Power Supplies 007 4566 001 185 Figure 6 23 Installing the power supply Bezel door Screen cover Ribbon cable D C A B ...
Страница 228: ......
Страница 262: ......
Страница 274: ......