8
TEST FUNCTIONS
D
IAGNOSTICS
[F4]
In the event of faulty operation, check the
different parts of the machine with the
“Diagnostics” function.
If the TEST gives undesirable results, see
chapter 9.1 "Trouble shooting" and, if necessary,
contact the Silca Service Centre.
[F1] help
Press key F1 to gain access to the guide.
UP, DOWN:
arrow keys to scroll the
TESTS.
F10:
to select the test.
ESC:
to exit from menu.
Test 100 = Motors
With the
keys movement for the X axis
motor is activated.
With the
keys movement for the Y axis
motor is activated.
WARNING: do not move the motors continuously against
the mechanical end of run stops as with this function in
operation all the limit switch sensors are disactivated.
Test 101 = Sensors
When the head is taken manually all the way to
the limit switch on the Y axis (inwards on the
machine) the display goes from ICY=OFF a
ICY=ON.
When the head is taken to the limit switch on the
X axis (to the left) the display goes from ICX=OFF
a ICX=ON.
Test 102 = Clamp microswitch
Four boxes corresponding to the four clamp
detection microswitches appear on the display.
Press each microswitch in turn and check that the
indicator on the display goes from [OFF] to [ON]
in the relevant box.
Fig. 29
100 = Motors
Use arrows to move
axes.
Diagnostics
100 = Motors
101 = Sensors
102 = Micro clamp
UP,DOWN,F10=S e l e c t
ESC=Exit
102 = Micro clamp
Press the clamp code
micros
[OFF] [OFF] [OFF] [OFF]
101 = Sensors
Move the axes
towards the micro
ICX=OFF
ICY=ON
101 = Sensori
Spingere gli assi
verso i micro
ICX=ON
ICY=ON
102 = Micro clamp
Press the clamp code
micros
[OFF]
[ON]
[OFF] [OFF]