MARKER 2000
Operating manual - English
42
Copyright Silca 2002
9.8
Replacing the control circuit board
1) turn off the master switch and disconnect all the wiring to the machine.
2) turn the machine on its back and remove the four screws (U1) securing the bottom plate (U), which
can then be taken off (fig. 39).
3) disconnect all the connectors on the board (from 1 to 13, page 44).
4) with the special tool (U2) provided with the replacement board (fig. 41), release the five clips on the
board.
5) fit the new board, engaging with the special catches, and connect all the connectors, taking care not
to exchange the two connectors “10” and “11”. The other connectors are polarized and therefore
cannot be interchanged or fitted wrongly.
WARNING: after replacing the board, check that all parts of the machine are working properly, using the TEST
function (ch.8, page 33).
Fig. 41
9.9
Replacing and positioning the sensors
Replacing the Y axis sensor
1) turn off the master switch and remove the plug.
2) turn the machine onto its back, remove the four screws securing the bottom plate (U) and remove
(fig. 39).
3) disconnect the Y sensor connector (9) (page 44).
4) stand the machine upright again, remove the cover (Q) (ch.9.4) and place next to the machine,
without disconnecting the display connector.
5) loosen the nut (Y4), unscrew the sensor from the plate (Y1) and remove (fig. 42).
6) place the new sensor in position and screw down until it almost contacts the plate (X1) (maintain a
distance of approximately 0,4 mm) and secure with the nut (Y4).
7) guide the Y sensor wire into the machine, then turn it on its back again.
8) connect the Y sensor connector (9) (page 44) to the electronic circuit board.
9) replace the bottom plate (U) and stand the machine upright.
10) connect the marking machine and proceed with “SETTING the ZEROES” (ch.7).