SMARTY 2000
Operating manual - English
20
8.3
Replacing the belt
Worn or loose belt must be replaced or adjusted so as to ensure safe and proper operation of the cutting
tool/ brush. Proceed as follows:
ATTENTION: remove the mains plug.
1) remove the motor cover (E1) by loosening the screws (E2) (fig.4, page 8).
2) loosen the four screws which fix the motor to the base.
3) raise the motor and remove the worn belt.
4) fit the new belt.
5) push the motor down until the proper belt tension is obtained.
6) tighten the four screws.
8.4
Replacing the tracer point
To replace the tracer point (C) proceed as follows (fig.14):
ATTENTION: remove the mains plug.
1) loosen the screw (C1).
2) loosen the screw (C2) until the tracer point (C) is fully released.
3) fit the new tracer point.
4) tighten the screw (C1) and secure the tracer point.
5) re-set the machine as described in this manual (ch.6, page 15).
Fig. 14
8.5
Replacing the fuses
ATTENTION: remove the mains plug.
1) turn the key-cutting machine so that the fuse box is easily reached.
2) remove the fuses box placed below the key-cutting machine socket (fig.15).
3) replace the fuses (U).
4) close the fuses box and connect the power cable.
ATTENTION: fuses must always be replaced with others of the same type (rapid) and with the same Amps (4
Amps for 230V machines, 6,3 Amps for 110V machines).
Fig. 15
C2
C
C1
U