MSK320
Commissioning English
MSK320 · Date
02.11.2017 · Art.
No.
80353 · Mod.
status
323/17
32
5 Commissioning
Following correct mounting and wiring you can put the measuring system
into operation by switching on operating voltage.
The measuring system is a component of an incremental measuring system
that must be referenced at a defined position (reference point) to make
absolute measurement possible.
6 Trouble shooting
Below are some typical errors which may occur during installation and
operation:
•
Magnetic tape wrongly mounted, active side below (see chapter
4.2
).
•
The masking tape provided was not used for protecting the magnetic
tape. The masking tape must not be magnetizable.
•
Magnetic sensor not or incorrectly connected (pin assignment see
chapter
4.5
).
•
The distance tolerances were not observed over the whole measuring
length (see
Fig. 6
,
Fig. 8
...
Fig. 11
).
•
Cable squeezed / interrupted / cut by sharp edges.
•
The magnetic sensor has been mounted with the active side turned
away from the band (see
Fig. 6
,
Fig. 8
).
•
Magnetic sensor has not been aligned according to
Fig. 6
,
Fig. 8
...
Fig. 11
.
7 Transport, Storage, Maintenance and Disposal
Transport and storage
Handle, transport and store the magnetic sensor with care. Pay attention
to the following points:
•
Transport and / or store the magnetic sensor in the unopened origi-
nal packaging.
•
Protect the magnetic sensor from harmful physical influences includ-
ing dust, heat and humidity.
•
Do not damage connections through mechanical or thermal impact.
•
Prior to installation inspect the magnetic sensor for transport dam-
ages. Do not install damaged magnetic sensors.