MSK320
Installation English
MSK320 · Date
02.11.2017 · Art.
No.
80353 · Mod.
status
323/17
25
4.3 Mounting the magnetic sensor
Alignment of the magnetic sensor
`
Take care that the magnetic sensor is aligned correctly in order to
ensure optimum sensing (see
Fig. 6
).
1. Mount magnetic tape (see chapter
4.2
).
2. Fasten the magnetic sensor, design A+AM+ZM via the thru-holes (2x
ø3.5 mm) on an even work surface (for the fastening dimensions refer
to the Data Sheet). We recommend to use the enclosed fixing screws
and washer springs (fastening torque design A = 0.25 Nm, design
AM+ZM = 1 Nm).
Magnetic sensor design F can be mounted e. g. to a mounting square
with a corresponding mounting bore by tightening the two nuts
M8x0.5.
LINEAR application:
MSK320 design ZM with MB320/1:
Fig. 6: Definition of the counting direction with magnetic tape and
assemblage sensor / magnetic tape, gap measure, tolerances
7
5
6
8
3
1
2
4
MBxxxx GEK WT RP NNNNNN
<1°
<3°
<3°
1
Active side magnetic tape
2
Travel direction signal A before
B
3
Direction of outgoing cable
4
Admissible deviation of tape/
sensor
0.1 ... 2 mm reference point O, I
0.1 ... 1.5 mm reference point R
0.4 ... 1 mm reference point FR
5
Maximum alignment error
6
Admissable deviation middle of
tape/sensor
ref. O, I ±2 mm
ref. R, FR ±0.5 mm
7
Position of the reference point
relating to the marking on the
magnetic tape
8
Flexible reference mark for
design ZM, mounted by the cus-
tomer (see chapter
8
)
NOTICE