MSK320
Installation English
MSK320 · Date
02.11.2017 · Art.
No.
80353 · Mod.
status
323/17
28
MSK320 design F with MRI01 or MR320:
1
Admissible deviation of
ring/sensor 0.1 ... 2 mm
2
Direction of rotation of mag-
netic ring signal A before B
3
Magnet
4
Undercut at the solid shaft
for tread plug is recom-
mended
5
Metallflange
Fig. 10: Definition of the counting direction with magnetic ring
and assemblage sensor/magnetic ring, gap measure, tolerances
4
3
5
1
2
<3°
MSK320 design F with MRF320:
Fig. 11: Definition of the counting direction with magnetic ring
and assemblage sensor/magnetic ring, gap measure, tolerances
1
2
<3°
1
Admissible deviation of
ring/sensor 0.1 ... 2 mm
2
Direction of rotation of mag-
netic ring signal A before B