MSK320
Installation English
MSK320 · Date
02.11.2017 · Art.
No.
80353 · Mod.
status
323/17
27
Magnetic ring MRI01
Slide magnetic ring MRI01 onto the shaft and then tighten grub screw M4
to fix it to the shaft.
1. Ensure sliding fit between shaft and MRI01.
2. Mount MRI01 without force and without strain. Possible forces should
go to the metal flange. Avoid knocks on the magnetic ring.
3. Provide for a relief groove in the solid shaft (see
Fig. 9
,
Fig. 10
).
Magnetic ring MRF320
Glue type "UHU Endfest 300" (or similar one) is used to fix magnetic ring
MRF320 to the shaft.
1. To ensure a concentric running of magnetic ring MRF320 the glueing
surface should be keyway like. Make sure that the glue is only inside
the keyway. Apply glue and then immediately fix magnetic ring. Please
also observe glue manufacturer's instructions regarding hardening
time (24 hours).
RADIAL application:
MSK320 design ZM with MRI01 or MR320:
1
Direction of outgoing cable
2
Admissible deviation of
ring/sensor
0.1 ... 2 mm reference point
O, I
0.1 ... 1 mm reference point
R
3
Direction of rotation of mag-
netic ring signal A before B
4
Reference point
5
Undercut at the solid shaft
for tread plug is recom-
mended
6
Admissable deviation middle
of tape/sensor
ref. O, I ±2 mm
ref. R ±0.5 mm
Fig. 9: Definition of the counting direction with magnetic ring
and assemblage sensor/magnetic ring, gap measure, tolerances
<3°
<3°