MSA213C-S (BiSS/C)
Documentation English
MSA213C-S (BiSS/C) · Date 24.05.2022 · Art. No. 90036 · Mod. status 111/22
15
1 Documentation
There are further relevant documents - see list in original installation
instruction.
These documents can also be downloaded at "
com/p/msa213c
".
1.1 History
Mod. status Date
Description
340/18
19.04.2021 Document prepared
111/22
23.05.2022 Text in chapter 7 changed
Designations changed in Fig. 3
2 Safety information
Safety information of original installation instruction apply.
3 Start-up
Following proper mounting and wiring of the measurement system con-
sisting of MSA213C sensor and MBA213 magnetic band, the system can
be put into operation by applying the operating voltage in the specified
range (see installation instruction MSA213C).
3.1 Calibration of the measurement system
The factory default calibration value is 0. The sensor outputs the absolute
value of the magnetic tape as a position value (0 … 16383999 µm). Since
the magnetic tape is composed of rolled goods, a zero point must be set
in the sensor at the desired position (only then does the sensor count cor-
rectly over the entire measuring length).
MSA213C is an absolute measurement system; i. e., the information of the
position value is embodied in the scale (MBA213 magnetic band) as an
absolute value. Various commands can be used to adjust the measuring
range in service mode (see chapter
4 Measurement range
In the following, the commands for determining the measuring range are
shown by way of examples.
NOTICE