MA10/4-SW02

 

Date: 06.05.2014 

Page 7 of 23 

Art.No. 87185 

Mod. status 422/13 

Display 

Value range 

Description 

TRS: 

n.open, 
n.closed, hand 

Reference switch 
Type of reference value transmitter; can either be a 
mechanical contact or a proximity switch. 
'n.open' closing contact, which is normally open 
'n.closed' opening contact, which is normally closed 
'hand' Referencing arbitrarily via callipers independent of 
A and B, index signal). The input is current-sinking and 
edge-triggered. 

REF: 

-999999 ... 
+999999 

Reference point for the measuring system 
Absolute datum point of the measuring system. This value 
is set after system reference accord. to chapter 

8

. 

value range modulo: 
-999999...+999999 
value range 0 0-90-0: 
-999999...+90 (resolution 1°) 
-999999...+900 (resolution 0.1°) 
-999999...+9000 (resolution 0.01°) 

OFF: 

-999999 ... 
+999999 

Offset (displacement) 
Menu item appears only if 'WINK:' has been programmed 
with 'modulo'. Freely selectable value that influences the 
display. The offset value can be used as tool correction or 
offset measure for instance. 

RESET: 

off, on, del.1s, 
del.3s 

Reset via keyboard enable 
'off' reset function off 
'on' reset function enabled 

'del.1s' reset function enabled (press key 

 for at least 

1 sec.) 

'del.3s' reset function enagled (press key 

 for at least 

3 sec.) 

ABS/REL: 

off, on 

Incremental measurement enable 
Menu item will be displayed only if 'modulo' is 
programmed for 'WINK:'. To switch from absolute 
measurement and zero-zetting to relative measurement. 
'off' function off 
'on' function on 

RE/OF.EN: 

off, on 

Reference/ offset value input enable 
Menu item will be displayed only if 'modulo' is 
programmed for 'WINK:'. 
'off' reference/offset value correction off 
'on' reference/offset value correction enabled 

RE/EN: 

off, on 

Reference value input enable 
Menu item will be displayed only if '0-90-0' is programmed 
for 'WINK:'. 
'off' reference value correction off 
'on' reference value correction enabled 

STO: 

off, on 

Actual value store 
When switched off, the last displayed value is stored in a 
non-volatile memory. 
'off' Actual value memory off: when switched on, the 
display must be calibrated (zeroed) (Display value is 
flashing). 
'on' Actual value memory on: when switched on, the last 
measured value is displayed. 

Содержание MA10/4

Страница 1: ...User manual Electronic display MA10 4 Software SW02...

Страница 2: ...teration of reference offset value or calibration offset value 12 6 4 Direct input of limiting value 12 7 0 90 0 Angle display 13 7 1 Input of limit with switching output option 13 8 Referencing Calib...

Страница 3: ...10 4 SW02 can be used for measuring angles in three ranges of resolution 1 0 1 0 01 After reaching the respective maximum value e g 359 programmable modulo value the display jumps to 0 With opposite s...

Страница 4: ...he input mode 1 2 3 4 5 6 7 8 9 10 11 12 Digit R 1 5 9 9 Angle value Digit Symbol Description 1 R Incremental measure is active 3 Upper limiting value exceeded only for output circuit option 3 Lower l...

Страница 5: ...y until the end of the parameter list is reached To scroll parameter information Use key Input of numerical values For numerical values the smallest decade flashes first The numerical value of the fla...

Страница 6: ...fter 1 revolution Value by which the display increases decreases after 1 revolution of the encoder If DPR 0 quadruple evaluation of the encoder signal will take place automatically DIVISOR 1 10 100 10...

Страница 7: ...n or offset measure for instance RESET off on del 1s del 3s Reset via keyboard enable off reset function off on reset function enabled del 1s reset function enabled press key for at least 1 sec del 3s...

Страница 8: ...value Menu item will be displayed only if SCHALT is programmed for BAUD Possibility of input modification of the upper and lower limiting values in the input mode off Modification of limiting values d...

Страница 9: ...al encoder bit number DPR 0 59999 Display after 1 revolution Menu item will be displayed only if multi is programmed for E TYP Value by which the display increases decreases after 1 revolution of the...

Страница 10: ...TPUT gray bin Output code gray Encoder s data in Gray code bin Encoder s data in binary code TIMEOUT off on Time out function off Cable break recognition off on Cable break recognition off P KEY 3s 5s...

Страница 11: ...med to on del 1s or del 3s but unit must not be left in programming mode see chapter 4 To leave programming mode For modulo display mode Press key to set the display to reference calibration offset va...

Страница 12: ...once again The display then shows the offset value which can be changed via the two arrow keys By pressing the key the value is saved and directly taken over in the display Finishing direct input of r...

Страница 13: ...Input of limit with switching output option When entering the limits that are in the quadrant 1 please note that they cannot be entered directly as with quadrant 0 but must be calculated according to...

Страница 14: ...ogrammed to 0 8 2 Automatic referencing Only incremental Automatic referencing is always made via a reference point transmitter which is automatically approached at a defined position reference value...

Страница 15: ...ving spindle if you untighten the clamping ring or coupling You can now search the index signal of the encoder voltage change by using for example a voltmeter and carry out the adjustment of the refer...

Страница 16: ...dditional parameters The MA10 4 transmits its answer with automatic Carriage Return CR Input Lower and upper cases are accepted ASCII Output All response telegrams are completed with a CR hex 13 excep...

Страница 17: ...ber of pulses y 2 positions after the comma y 4 encoder bits SSI only y 5 singleturn bits SSI only y 6 modulo value Iabc 4 2 Release frontal keys a reset via keyboard 0 off 1 on 2 1 sec delay 3 3 secs...

Страница 18: ...1 3 xyz Binary position value xyz 3 bytes in two s complement MSB LSB Xy 2 2 Enter unit of measure y number y 0 no y 1 angle degree Yx 2 2 Enter display divisor incremental and SSI only x number x 0...

Страница 19: ...ted command 0x32 0x33 R This command can be broadcasted Hex TX RX S P R Function 0x16 3 6 Read out position value 0x18 3 6 Read out reference calibration value 0x19 3 6 Read out offset value 0x1b 3 6...

Страница 20: ...6 6 S P Program index type only incremental see command 0x6c 0x72 3 6 Output configuration bits 0x73 6 6 S P Program configuration bits 0x7e 3 6 Send type of reference switch only incremental 0x7f 6 6...

Страница 21: ...tho be installed on a mitre box saw While the saw blade is swinging the measured value shall decrease from 90 in the direction of 0 on both sides An incremental encoder with 100 pulses per revolution...

Страница 22: ...l value store programmed to off Carry out reference calibration 12 Parameter list 12 1 Incremental version Display Selection value Default value Your own programming use 1 2 3 LANGUAGE deu eng deu WIN...

Страница 23: ...lo 0 90 0 modulo DEC 0 0 0 0 00 0 0 MOD W 0 59999 360 0 E TYP multi single multi FORMAT no Tree no S BITS 5 19 10 ENCOD BIT 5 25 22 DPR 0 59999 0000 0 DIVISOR 1 10 100 1000 1 DIRECTION i e i CAL 99999...

Отзывы: