Display
Value range
Description
TRS:
n.open,
n.closed, hand
Reference switch
Type of reference value transmitter; can either be a
mechanical contact or a proximity switch.
'n.open' closing contact, which is normally open
'n.closed' opening contact, which is normally closed
'hand' Referencing arbitrarily via callipers independent of
A and B, index signal). The input is current-sinking and
edge-triggered.
REF:
-999999 ...
+999999
Reference point for the measuring system
Absolute datum point of the measuring system. This value
is set after system reference accord. to chapter
value range modulo:
-999999...+999999
value range 0 0-90-0:
-999999...+90 (resolution 1°)
-999999...+900 (resolution 0.1°)
-999999...+9000 (resolution 0.01°)
OFF:
-999999 ...
+999999
Offset (displacement)
Menu item appears only if 'WINK:' has been programmed
with 'modulo'. Freely selectable value that influences the
display. The offset value can be used as tool correction or
offset measure for instance.
RESET:
off, on, del.1s,
del.3s
Reset via keyboard enable
'off' reset function off
'on' reset function enabled
'del.1s' reset function enabled (press key
for at least
1 sec.)
'del.3s' reset function enagled (press key
for at least
3 sec.)
ABS/REL:
off, on
Incremental measurement enable
Menu item will be displayed only if 'modulo' is
programmed for 'WINK:'. To switch from absolute
measurement and zero-zetting to relative measurement.
'off' function off
'on' function on
RE/OF.EN:
off, on
Reference/ offset value input enable
Menu item will be displayed only if 'modulo' is
programmed for 'WINK:'.
'off' reference/offset value correction off
'on' reference/offset value correction enabled
RE/EN:
off, on
Reference value input enable
Menu item will be displayed only if '0-90-0' is programmed
for 'WINK:'.
'off' reference value correction off
'on' reference value correction enabled
STO:
off, on
Actual value store
When switched off, the last displayed value is stored in a
non-volatile memory.
'off' Actual value memory off: when switched on, the
display must be calibrated (zeroed) (Display value is
flashing).
'on' Actual value memory on: when switched on, the last
measured value is displayed.