MA10/4-SW02
Date: 06.05.2014
Page 22 of 23
Art.No. 87185
Mod. status 422/13
Example:
Magnetic ring MR500: Pole number = 64
Magnetic sensor MSK500: Scaling factor = 125
-> Encoder pulses per revolution = 64 x 125 = 8000
11
Trouble shooting
Error states are recognized and shown in the display.
Messange
Description
Action
FULL
Display overrun
Control parameters and adjust them if
necessary; reference/calibration display.
Flashing
display
Device was switched on with
actual value store programmed
to 'off'.
Carry out reference/calibration.
12
Parameter list
12.1
Incremental version
Display
Selection/value
Default
value
Your own programming use
1
2
3
LANGUAGE:
deu, eng
deu
WINK:
modulo, 0-90-0
modulo
DEC:
0., 0.0, 0.00
0.0
MOD.W:
0 ... 59999
360.0
DPR:
0 ... 59999
0000.0
DIVISOR:
1, 10, 100, 1000
1
INCR:
0 ... 59999
00000
DIRECTION:
i, e
i
INDEX:
I-lang, 0-lang, I-kurz, 0-kurz
I-lang
TRS:
n.open, n.closed, hand
n.open
REF:
-999999 ... +999999
+00000.0
OFF:
-999999 ... +999999
+00000.0
RESET:
off, on, del.1s, del.3s
off
ABS/REL:
off, on
off
RE/OF.EN:
off, on
off
RE.EN:
off, on
off
STO:
off, on
off
P-KEY:
3s, 5s, 10s, 20s, 30s
5s
BAUD:
2400, 4800, 9600, 19200,
SIKON.3, SCHALT
4800
ADR:
1 ... 31
31