MA10/4-SW02
Date: 06.05.2014
Page 11 of 23
Art.No. 87185
Mod. status 422/13
Display
Value range
Description
UNITS:
--, °
Unit of measure
Choice of the measurement unit to be displayed on
positions 11, 12 (see chapter
DIS.ANGLE:
-5 ... +4
Display angle
Here, the contrast of the LC display can be set.
SET:
Encoder zeroing
Zeroing of the encoder (+calibration value) in
programming mode via
key.
GDAT:
Position value of the encoder
Display of the actual encoder position.
CODE:
00000
Code input: for special functions
CONTROL:
off, on
Code input: for special functions
6
Input mode
6.1
Reset function
Precondition: Parameter 'Reset enable' (RESET:) in programming mode must
be programmed to "on", "del.1s" or "del.3s" but unit must not be left in
programming mode (see chapter
For "modulo" display mode
Press key
to set the display to reference/calib offset value.
For "0-90-0" display mode
Press key
to set the display to reference/calibration value.
6.2
Incremental measurement
(Not 0-90-0 display mode!)
Precondition: Menu item 'Incremental measurement enable' (ABS/REL:) in
programming mode must be programmed to "on", but unit must not be left in
programming mode (see chapter
Switching on by pressing the
key.
The display is zeroed and an "R" is displayed on position 1.
Switchin off by pressing the
key once more. The absolute measuring value is displayed
again.
While in the incremental measurement mode the display can also be set to zero by pressing
key
. This does not change the absolute measurement in the background.