Operating Manual MH 3750

Page 8

8/11

5 Operation Of Logger

The device supports two different logger functions:

„Func-Stor“:

each time when „store“ (key 6) is pressed a measurement will be recorded.

„Func-CYCL“:

measurements will automatically be recorded at each interval, which was set in the logger menu 
‚CYCL‘ until the logger will be stopped or the logger memory is full. The recording is started by 
pressing „Store“ 2 seconds.

The logger records 1 measurement result each time
For the evaluation of the data the software GSOFT3050 (V1.7 or higher) has to be used. The software also allows easy 
configuration and starting of the logger.

When the logger is activated (Func Stor or Func CYCL) the hold function is no longer available, key 6 is solely used for 
the operation of the logger functions.

5.1 „Func-Stor“: Storing Single Measurements

Each time when „store“ (key 6) is pressed a measurement and its time stamp will be recorded. 
The recorded data can be viewed either in the display (when calling the configuration an additional menu „REAd LoGG“ 
is displayed, see below) or by means of the interface and a PC with GSOFT3050-software.

Max. number of measurings:

99

A measuring contains:

- current measuring value at the time of recording 
- time and date of the recording

After each recording „St. XX“ will be displayed for a short time. XX represents the number of the recording.

When logger memory contains recordings already:

When „Store“ is pressed for 2 seconds, the choice for clearing the logger memory will be displayed:

The selection can be made by 

5

 (key 2) and 

6

 (key 5). "Quit" (key 6) enters the choice.

If the logger memory is full, the display will show: 

Viewing Recorded Measurings

Within the „LoGG Stor“ function the measurings can be viewed directly in the display not only by means of a computer 
(like at „Func CYCL“): press 2 seconds „Set“ (key 4): The first menu displayed now is „rEAd LoGG“ (read logger data). 
After pressing 

4

 (key 3)  the measurement recorded last will be displayed, changing between the different data 

referring to the measurement also is done by pressing 

4

Changing the measurement is done by pressing the keys 

5

 or 

6

.

Clear all 
recordings

Clear the last 
recording 

Clear nothing 
(cancel menu)

SIKA, Dr. Siebert & Kühn GmbH & Co. KG, Struthweg 7-9, 34260 Kaufungen, Germany

 

Tel: +49-5605-803-0, Fax: +49-5605-803-54, email: [email protected], web: www.SIKA.net

Содержание MH 3750

Страница 1: ...ert K hn GmbH Co KG Struthweg 7 9 34260 Kaufungen Germany Tel 49 5605 803 0 Fax 49 5605 803 54 email info SIKA net web www SIKA net Operating Manual Precision Thermometer MH 3750 from Version 1 0 For...

Страница 2: ...old to a warm environment condensation may result in a failure of the function In such a case make sure the device temperature has adjusted to the ambient temperature before trying a new start up 3 If...

Страница 3: ...nfiguration menu 1 3 Connections 1 Output Operation as interface Connect to optically isolated interface adapter accessory GRS 3100 or GRS3105 Operation as analogue output Connection via suitable cabl...

Страница 4: ...ed no interface communication takes place oFF Power off function inactive continuous operation e g mains operation oFF Function of the output No output function lowest power consumption SEr Output is...

Страница 5: ...heat loss caused by the probe is not considered When measuring fluids therefore the probe should be emerged sufficiently deep and be stirred continuously When measuring gases the probe should also eme...

Страница 6: ...ed Together with the zero displacement see above this factor is mainly used to compensate for sensor deviations Unless the factor is set to off the Corr arrow in the display shows an active scale corr...

Страница 7: ...ogue Output Scaling with DAC 0 and DAC 1 With the DAC 0 and DAC 1 values the output can be rapidly scaled to Your efforts Keep in mind not to connect low resistive loads to the output otherwise the ou...

Страница 8: ...w or by means of the interface and a PC with GSOFT3050 software Max number of measurings 99 A measuring contains current measuring value at the time of recording time and date of the recording After e...

Страница 9: ...lly will be stopped Stopping the recording manually By pressing Store key 6 the recording can be stopped manually Then the following choice appears The selection can be made by 5 key 2 and 6 key 5 Qui...

Страница 10: ...nnect sensor to socket sensor cable or device defective return to manufacturer for repair Value exceeding measuring range Check Is the value exceeding the measuring range specified temperature too hig...

Страница 11: ...is done by integrated horn display and interface Real time clock Integrated clock with date and year Logger 2 Functions individual value logger Func Stor and cyclic logger Func CYCL Memory Stor 99 da...

Отзывы: