30
TROUBLESHOOTING, Continued
#13 CONDITION: Sealing mechanism stalls in down position.
CAUSE
REMEDY
1.
Insufficient air pressure to complete
sealing.
2.
Broken sealer mechanism part.
1.
Increase air pressure until sealing is
completed.
WARNING - Air pressure must be maintained
in the 65-90 psig range.
2.
Carefully inspect sealer mechanism for
broken parts. Jaw stack can be
returned to the up position by inserting
screw driver in slot in sure seal pawl
and rotating clockwise.
WARNING - Stand to side of and hold tool
securely when rotating pawl on jammed tool.
#14 CONDITION: Tool will not cut off strap after sealing.
CAUSE
REMEDY
1.
Cutter blade out of adjustment.
2.
Cutter blade worn.
3.
Cutting leg on cutter block worn or
broken.
1.
Adjust cutter.
2.
Replace cutter blade.
3.
Replace cutter block.