26
TROUBLESHOOTING, Continued
#2 CONDITION: Air motor runs slowly or sluggishly.
CAUSE
REMEDY
1.
Air supply to tool is restricted.
2.
Air motor filter screen is blocked with
rust or dirt.
3.
Air motor is dry, unlubricated, causing
motor to run slowly.
1A.
Check gauge on FRL for proper 65-90
psig pressure setting.
1B.
Check air line from FRL for blockage
1C.
Check for satisfactory air volume
reaching tool by either of the following
methods:
a.
Install an in-line air gauge at the tool if
one is available. Hook up air and record
pressure reading. With no strap in tool,
press tension lever and record gauge
reading. If pressure drops more than 15
psig, air supply is inadequate. Remedy
is to improve air flow by shortening
length of line from FRL to tool,
increasing size of air lines, or checking
for obstructions to or from FRL unit.
Example: If piping system equipped
with shutoff valves, ensure valve are
fully open.
b. If no in-line gauge available, repeat step
"a", above, except use gauge on FRL
unit.
2.
Check air motor filter screen for
obstruction then clean or replace as
required.
3.
Add teaspoon air line oil directly into
the motor at elbow. Place rag around
motor, reconnect air and test. If motor
speed increases, motor was dry. Check
lubricator for proper adjustment,
quantity and type of oil.
Содержание AMPT-12
Страница 1: ...SIGNODE 3620 WEST LAKE AVENUE GLENVIEW ILLINOIS 60025 AMPT 12 POWERED COMBINATION STRAPPING TOOL...
Страница 14: ...14 Apply one drop of Loctite 242 Sealant to cleaned parts Allow 12 hours to set if possible Use Loctite 609...
Страница 15: ...15...
Страница 16: ...16 Apply one drop of Loctite 242 Sealant to cleaned parts Allow 12 hours to set if possible...
Страница 21: ...21...