7 of 12
ÐSIGNET
5600 Batch Controller
10.4 OPTIONS Menu
(factory defaults shown in menu column 1)
Count Direction:
Up Down
To return
to VIEW:
To restore original value:
quick
press
quick
press
H.
Option Contact:
Missing Signal >
Option contact
Option Contact:
Missing Signal
Missing
Signal
Set operation mode (sec. 9.2):
Current Output:
End of Batch
Current Output:
Valve Control
J.
Current Output:
BatchCompletion>
Current output
Current Output:
Batch Completion
Batch
Completion
Valve
Control
End of
Batch
Set operation mode (sec. 9.2):
←
To step A
Two Stage
Setpoint%: 95.0>
Set two stage
setpoint %:
0.00 - 100.
Option Contact
Two Stage
Setpoint%: 99.5
Two Stage mode selected
NOT shown if Missing Signal Alarm is Off (step H)
I.
Missing Signal
Delay: 30.0 sec >
Option Contact
Set missing
signal time
delay: 0.10 -
999. sec.
Missing Signal
Delay: 25.0 sec
K.
Count Direction:
Up >
Batch display count
Batch display
count direction:
Up or Down
Overrun Volume:
0.00000 Gallons>
Set overrun
volume:
0.00000 -
999999.
Batch contact
Overrun Volume:
0003.75 Gallons
G.
Set overrun
compensation:
automatic
or manual
(sec. 9.2)
Batch contact
Overrun Comp:
Manual >
Overrun Comp:
Auto Manual
M
anual
overrun
comp
selected
(
step
G):
←
Back to step F
Overrun Alarm:
1.00000 Gallons>
Set overrun alarm
volume: 0.00001 -
999999.
Option Contact
Overrun Alarm:
0002.50 Gallons
Overrun Alarm mode selected
Missing Signal
Alarm: On >
Missing signal
alarm:
On or Off
Option Contact
Missing Signal
Alarm: Off On
Two Stage, Overrun Alarm, End of Batch, or Off
mode selected
ENTER
"SAVING"
briefly
displays
Option Contact:
End of Batch
End of
Batch
Option Contact:
Two Stage
Two
Stage
Option Contact:
Overrun Alarm
Overrun
Alarm
Option Contact:
Off
Turn
off
To return
to VIEW:
To restore original value:
quick
press
quick
press
OPTIONS: -- -- -- --
Enter Key Code
Press keys in sequence
to continue,
**** will appear during code entry.
Contrast:
3 >
A.
B.
C.
Choose:
1
Change:
2
Save:
3
Set contrast:
5 levels
Contrast
Set flow decimal:
******
. -
**
.
****
Flow decimal
Total Decimal:
*******
.
*
>
Set totalizer
decimal:
********
. -
******
.
**
Totalizer decimal
ENTER
D.
Lock:
OFF >
Set VIEW Menu
lock:
On= Off=
VIEW Menu Lock
Contrast:
1 2 3 4 5
Display Decimal:
****
.
**
Total Decimal:
******
.
**
Lock:
Off On
E.
Operating Mode:
Advanced >
Operation mode
Set operation
mode:
Simple or
Advanced F - H
F.
Pulse Output:
Totalizer >
Pulse Output
End of Batch
(EOB)
Totalizer
(CNT)
Pulse Output:
End of Batch
Pulse Output:
Totalizer
Set pulse output (sec. 9.2):
Advanced mode selected (step E)
To step G
→
"SAVING"
briefly
displays
K
↓
Display Decimal:
*****
.
*
>
Operating Mode:
Simple Advanced
Menu Navigation
• Advanced mode chosen (step E): menu continues, steps F - I.
• Simple mode chosen (step E): down arrow key advances to
top of menu (step A).