5600 Batch Controller

10.4  OPTIONS Menu

 

(factory defaults shown in menu column 1)

   Count Direction:
       Up    Down

To return 
to VIEW:

To restore original value:

quick 

press

quick 

press

H.

   Option Contact:      
   Missing Signal  >

Option contact

   Option Contact:
   Missing Signal

Missing 
Signal

Set operation mode (sec. 9.2):

  Current  Output:
  End of Batch

  Current  Output:
   Valve Control

J.

 Current  Output:
 BatchCompletion>

Current output

  Current  Output:
  Batch Completion

Batch 
Completion

Valve 
Control

End of
Batch

Set operation mode (sec. 9.2):

To step A

      Two Stage
 Setpoint%:  95.0>

Set two stage 
setpoint %:  
0.00 - 100.

Option Contact

      Two Stage
  Setpoint%: 99.5 

Two Stage mode selected

NOT shown if Missing Signal Alarm is Off (step H)

I.

 Missing Signal
 Delay: 30.0 sec >

Option Contact

Set missing 
signal time 
delay: 0.10 - 
999. sec.

 Missing Signal
 Delay: 25.0  sec

K.

   Count Direction:
            Up       >

Batch display count

Batch display 
count direction:
Up or Down

 Overrun Volume:
 0.00000 Gallons>

Set overrun 
volume: 
0.00000 - 
999999.

Batch contact

 Overrun Volume:
 0003.75 Gallons  

G.

Set overrun 
compensation:  
automatic 
or manual 
(sec. 9.2)

Batch contact

   Overrun Comp:
        Manual      >

   Overrun Comp:
    Auto   Manual

M

anual

 

overrun

 

comp

 

selected

  (

step

  G):

Back to step F

   Overrun Alarm:
1.00000 Gallons>

Set overrun alarm
volume: 0.00001 - 
999999.

Option Contact

   Overrun Alarm:
 0002.50 Gallons

Overrun Alarm mode selected

 Missing Signal
 Alarm:       On   >

Missing signal
alarm: 
On or Off

Option Contact

 Missing Signal
 Alarm:  Off   On 

Two Stage, Overrun Alarm, End of Batch, or Off

mode selected

ENTER

"SAVING"

briefly

displays

   Option Contact:
    End of Batch

End of
Batch

   Option Contact:
     Two Stage

Two 
Stage

   Option Contact:
   Overrun Alarm

Overrun 
Alarm

 Option Contact:
          Off

Turn
off

To return 
to VIEW:

To restore original value:

quick 

press

quick 

press

OPTIONS:  -- -- -- --
Enter Key Code

Press keys in sequence 

              

          to continue,

****  will appear during code entry.

       Contrast:
             3         >

A.

B.

C.

Choose:

1

Change:

2

Save:

3

Set contrast:
5 levels

Contrast

Set flow decimal:

******

.  - 

**

.

****

Flow decimal

    Total Decimal:

  

*******

 . 

*

>

Set totalizer 
decimal:

********

.  - 

******

.

**

Totalizer decimal

ENTER

D.

         Lock:
          OFF        >

Set VIEW Menu 
lock:

On= Off=

VIEW Menu Lock

      Contrast:
  1   2   3   4   5

  Display Decimal:

   

****

 . 

**

     Total Decimal:

  

******

**

          Lock:
       Off     On

E.

  Operating Mode:
        Advanced  >

Operation mode

Set operation 

mode:  

Simple or 

 Advanced F - H

F.

    Pulse Output:
       Totalizer      >

Pulse Output

End of Batch 
(EOB)

Totalizer 
(CNT)

    Pulse Output:
    End of Batch

    Pulse Output:
       Totalizer

Set pulse output (sec. 9.2):

Advanced mode selected (step E)

To step G

"SAVING"

briefly

displays

K

  Display Decimal:

    

*****

.

*

   >

  Operating Mode:
  Simple  Advanced

Menu Navigation

• Advanced mode chosen (step E):  menu continues, steps F - I.
• Simple mode chosen (step E):  down arrow key advances to

top of menu (step A).

Содержание GF 5600

Страница 1: ...mpedance sec 8A is affected by the supply voltage To reduce the possibility of noise interference isolate AC power lines from signal lines Double Insulated DC or AC power Contents 1 Wiring terminals 2 Power Connection 3 Compatible Sensor Wiring 4 Batch Contact Wiring 5 Remote Control Wiring 6 End of Batch Counter Pulse Output Wiring 7 Option Contact Wiring Options Technical Notes To reduce the pos...

Страница 2: ... EOB output External Counter Gnd IN 5 30 VDC 10 kΩ Rsm RTN Start Stop Remote Gnd CNT EOB output First 5600 Second 5600 B Daisy chaining two 5600 batch controllers together A External counter connection 5600 Terminals Technical Notes Use 2 conductor shielded twisted pair cable for output lines up to 30 m 100 ft max 6 End of Batch Counter Pulse Output Wiring See section 9 for simple and advanced mod...

Страница 3: ...on sec 8A This function is offered in the simple or advanced operation mode The output is a linear increase from 4 mA at batch start to 20 mA at batch end 9 2 Advanced Operation Mode Batch Contact sec 4 The batch contact is dedicated for on off control and is either manually or automatically compensated for batch overrun Manual overrun compensation allows the operator to compensate for valve closu...

Страница 4: ... batch start up An adjustable time delay entry in seconds is offered which specifies how long the instrument will wait after batch start up before initiating the missing signal alarm See simple operation mode sec 9 1 for alarm operation details Option Contact On Off sec 10 4H This function enables or disables the option contact and front panel option LED When the option contact is configured Off t...

Страница 5: ...t 1 min ENTER to Stop 10 Menu Functions Note BATCH VIEW Menu steps B E MUST be selected for CALIBRATE Menu sec 10 2 or OPTIONS Menu sec 10 4 access OPTIONS CALIBRATE VIEW 2s 5s Press hold for access ENTER 10 1 BATCH VIEW Menu example Menu steps B E cannot be accessed when a batch is running Press ENTER to stop batch cycle Steps B E MUST be selected for CALIBRATE Menu sec 10 2 or OPTIONS Menu sec 1...

Страница 6: ...ctor Auto Calibrate ENTER to Start Auto Calibrate Procedure Accurate reference container required See procedure sec 10 3 Start Stop ENTER ENTER ENTER Save Save Enter volume A Reenter volume Batch Units Liter Flow Time Base s S m M h H d D ENTER D Batch K Factor 60 000 Set batch K Factor 0 0001 99999 see note Batch K Factor G Last CAL Sets user defined date Last calibration E Set totalizer units Az...

Страница 7: ...Alarm 1 00000 Gallons Set overrun alarm volume 0 00001 999999 Option Contact Overrun Alarm 0002 50 Gallons Overrun Alarm mode selected Missing Signal Alarm On Missing signal alarm On or Off Option Contact Missing Signal Alarm Off On Two Stage Overrun Alarm End of Batch or Off mode selected ENTER SAVING briefly displays Option Contact End of Batch End of Batch Option Contact Two Stage Two Stage Opt...

Страница 8: ...ading Input Optically isolated Enclosure Rating NEMA 4X IP65 front Dimensions 1 4 DIN 96 x 96 x 88 mm 3 8 x 3 8 x 3 5 in Case materials ABS plastic Keypad material Sealed 4 key silicone rubber Weight Approximately 500 g 18 oz Display Type Microprocessor controlled air core meter movement and alphanumeric 2 x 16 LCD Update rate 200 ms Contrast User selected Alarm annunciators green batch LED left r...

Страница 9: ...24 V 10 W GF SIGNET Model 3 5600 Rsm RTN Gnd Start Stop Remote CNT EOB output Current output Dimensions 13 Quick Reference Menu Parameters 13 1 VIEW Menu Setup Parameters sec 10 1 Menu Parameters Factory Default Range Display Description Press ENTER to start stop or resume batch Programmed batch volume Resettable totalizer Permanent totalizer Overrun mode Overrun volume See programmed batch volume...

Страница 10: ... Batch Count up or down 3 Off Advanced Totalizer Manual 0 00000 Gallons Missing signal 95 0 1 00000 Gallons On 0 10 seconds Batch Completion Count up A B C D E F G H I J K Contrast 3 Total Decimal Lock OFF Operating Mode Advanced Pulse Output Totalizer Display Decimal Option Contact Missing Signal Current Output BatchCompletion Two Stage Setpoint 95 0 Missing Signal Delay 30 0 sec Count Direction ...

Страница 11: ... 10 2D can not be zero be zero Total K Factor Totalizer K Factor can not be Enter K Factor greater than zero sec 9 2E can not be zero zero Must be between Missing signal time delay must be se Enter missing signal time delay within 0 10 999 seconds sec 10 4I 0 10 999 for 0 10 999 seconds Overrun Volume Overrun alarm volumetric setting Enter overrun alarm volumetric setpoint within 0 00100 999999 ca...

Страница 12: ...nue El Monte CA 91731 2882 U S A Tel 626 571 2770 Fax 626 573 2057 For Worldwide Sales and Service visit our website www gfsignet com Or call in the U S 800 854 4090 GEORGE FISCHER Piping Systems 3 5600 090 1 D 6 03 English Signet Scientific Company 2001 Printed in U S A on recycled paper ...

Отзывы: