5 of 12
ÐSIGNET
5600 Batch Controller
Batch
Start
Stop
Resume
or
start
Main Batching Sequence
Save
ENTER
3.
Batch Volume:
Key Code: ****
Programmable
Batch Volume
B.
Batch Volume:
200.500 Gallons
Batch Volume:
200.500 Gallons
(sec. 10.4D)
OPTIONS =
(sec. 10.4D)
OPTIONS =
1. Enter volume
2. Enter volume
1. Enter code:
Batch Volume:
Key Code: -- -- -- --
Save
ENTER
2.
To exit without
changes:
quick
press
OR
Batch Volume:
100.000 Gallons>
Reset Total?
Key Code: ****
Gallons X 1
Total:1234567.8>
Resettable Totalizer
C.
Reset Total?
1234567.8
Reset Total?
0000000.0
Reset Total?:
1234567.8
Reset Total?:
0000000.0
(sec. 10.4D)
OPTIONS =
(sec. 10.4D)
OPTIONS =
1. Enter code:
Reset Total?
Key Code: -- -- -- --
Press to reset
ENTER
1.
Press to reset
ENTER
2.
2.
3.
To exit without
changes:
quick
press
OR
Permanent Total
D
.
Overrun: Manual
0.00000 Gallons
Overrun compensation
E
.
E.
Shown only when "advanced" mode is chosen
(sec. 10.4E)
D.
Permanent Total cannot be reset.
To step C
→
To Step E
→
←
Back to Step B
←
To step A)
A.
ENTER
ENTER
ENTER
Volume batched
40.3 Gallons
<ENTER> to Stop
Resume or start
40.3 Gallons
Resume Start
0.0 Gallons
<ENTER> to Start
Count Up
selected
(sec.10.4K)
While a batch
is running...
Volume batched
40.3 Gallons
<ENTER> to Stop
60.5 Gallons/m
<ENTER> to Stop
Time Left
Flow rate
Time Left: <1 min
<ENTER> to Stop
10. Menu Functions
*Note: BATCH/VIEW Menu steps B - E
MUST
be selected for
CALIBRATE Menu (sec. 10.2) or OPTIONS Menu (sec. 10.4)
access.
OPTIONS
CALIBRATE
VIEW
2s
5s
Press &
hold for
access:
ENTER
10.1 BATCH/VIEW Menu
(example)
• Menu steps B - E cannot be accessed when a batch is running. Press ENTER to stop batch cycle.
• Steps B - E
MUST
be selected for CALIBRATE Menu (sec. 10.2) or OPTIONS Menu (sec. 10.4) access.
Menus:
• BATCH/VIEW menu (sec. 10.1):
The BATCH/VIEW menu is
displayed during standard operation. The ENTER key controls
batch start, batch stop, and batch resume operations. While a
batch is not running, the operator can navigate freely through
the menu by pressing either UP or DOWN arrow keys. While
a batch is running, pressing either UP or DOWN arrow keys
displays Time left, Flow rate, and Volume batched information.
The BATCH/VIEW menu also offers a programmable batch
size and resettable totalizer feature that allows the operator to
reset the displayed total at the press of a button.
• CALIBRATE Menu (sec. 10.2):
The CALIBRATE menu
contains all critical display setup and output parameters. A
simple security code feature prevents unauthorized tampering.
The operator is required to enter a simple access code for
menu access. The same code also unlocks OPTIONS menus.
• OPTIONS Menu (sec. 10.4):
T
he OPTIONS menu contains
setup and display features that are seldom accessed for minor
display or output adjustments.