Signet 2537 Flowmeter

K-Factors

When using the PULSE DIVIDER output, associated equipment must divide the K-factors by the P-Factor.

PIPE
SIZE

(IN.)

FITTING 

2536/8512-XX

U.S. 

GAL

LITERS

SCH 80 PVC TEES FOR SCH 80 PVC PIPE

1/2

PV8T005

991.71

262.01

3/4

PV8T007

545.14

144.03

1  

PV8T010

352.44

93.114

1-1/4  

PV8T012

177.18

46.812

1-1/2

PV8T015

117.85

31.137

2  

PV8T020

66.739

17.633

2-1/2  

PV8T025

42.994

11.359

3

PV8T030

26.652

7.0414

4

PV8T040

15.006

3.9645

SCH 80 CPVC TEES FOR SCH 80 CPVC PIPE

1/2  

CPV8T005 991.71

262.01

3/4  

CPV8T007 545.14

144.03

1  

CPV8T010 352.44

93.114

1-1/4  

CPV8T012 177.18

46.812

1-1/2  

CPV8T015 117.85

31.137

SCH 80 PVC SADDLES FOR SCH 80 PVC PIPE

2  

PV8S020

66.739

17.633

2-1/2  

PV8S025

42.994

11.359

3  

PV8S030

26.652

7.0414

4  

PV8S040

15.006

3.9645

6  

PV8S060

8.3246

2.1994

8  

PV8S080

5.0164

1.3253

SCH 80 PVC SADDLE ON SCH 40 PVC PIPE

2  

PV8S020

54.700

14.452

2-1/2  

PV8S025

37.159

9.8175

3  

PV8S030

23.697

6.2608

4  

PV8S040

13.456

3.5552

6  

PV8S060

7.4594

1.9708

8  

PV8S080

4.5292

1.1966

PIPE
SIZE

(IN.)

FITTING 

2536/8512-XX

U.S. 

GAL

LITERS

CARBON STEEL TEES ON SCH 40 PIPE

1/2  

CS4T005

756.00

199.74

3/4  

CS4T007

438.69

115.90

1  

CS4T010

286.78

75.768

1-1/4  

CS4T012

121.22

32.026

1-1/2  

CS4T015

91.139

24.079

2  

CS4T020

54.468

14.391

STAINLESS STEEL TEES ON SCH 40 PIPE

1/2  

CR4T005

734.20

193.98

3/4  

CR4T007

412.10

108.88

1  

CR4T010

252.70

66.764

1-1/4  

CR4T012

128.12

33.849

1-1/2  

CR4T015

77.320

20.428

2  

CR4T020

45.780

12.095

GALVANIZED IRON TEES ON SCH 40 PIPE

1  

IR4T010

213.01

56.277

1-1/4  

IR4T012

127.75

33.751

1 1/2  

IR4T015

94.401

24.941

2  

IR4T020

59.420

15.699

BRONZE TEES ON SCH 40 PIPE

1  

BR4T010

213.01

56.277

1-1/4  

BR4T012

127.75

33.751

1-1/2  

BR4T015

94.401

24.941

2  

BR4T020

59.420

15.699

COPPER TEE FITTINGS ON COPPER PIPE 
SCH K

1/2  

CUKT005 917.84

242.50

3/4  

CUKT007 428.27

113.15

1  

CUKT010 256.43

67.749

1-1/4  

CUKT012 176.44

46.615

1-1/2  

CUKT015 115.69

30.565

2  

CUKT020 63.385

16.746

COPPER TEE FITTINGS ON COPPER PIPE 
SCH L

1/2   

CUKT005 858.22

226.74

3/4   

CUKT007 385.74

101.91

1   

CUKT010 241.64

63.841

1-1/4   

CUKT012 170.90

45.152

1-1/2   

CUKT015 112.03

29.598

2   

CUKT020 61.74

16.310

PIPE
SIZE

(IN.)

FITTING 

2536/8512-XX

U.S. GAL

LITERS

STAINLESS STEEL WELDOLETS ON SCH 40 
PIPE

2-1/2   

CR4W025    

37.600

9.9339

3  

CR4W030

24.340

6.4306

4  

CR4W040

13.920

3.6777

5  

CR4W050

10.860

2.8692

6  

CR4W060

7.5200

1.9868

8  

CR4W080

4.3400

1.1466

CARBON STEEL WELDOLETS ON SCH 40 PIPE

2-1/2  

CS4W025

37.600

9.9339

3  

CS4W030

24.340

6.4306

4  

CS4W040

13.920

3.6777

5  

CS4W050

10.860

2.8692

6  

CS4W060

7.5200

1.9868

8  

CS4W080

4.3400

1.1466

COPPER/BRONZE BRAZOLETS ON SCH 40 PIPE

2-1/2 BR4B025

37.600

9.934

3 BR4B030

24.340

6.431

4 BR4B040

13.920

3.678

5 BR4B050

10.860

2.869

6 BR4B060

7.5200

1.987

8 BR4B080

4.3400

1.147

SCH 80 IRON SADDLES ON SCH 80 PIPE

2 IR8S020

64.720

17.099

2-1/2 IR8S025

42.480

11.223

3 IR8S030

26.420

6.980

4 IR8S040

14.700

3.884

5 IR8S050

12.180

3.218

6 IR8S060

8.4400

2.230

8 IR8S080

4.9000

1.295

SCH 80 IRON SADDLE ON SCH 40 PIPE

2 IR8S020

53.640

14.172

2-1/2 IR8S025

37.600

9.934

3 IR8S030

23.220

6.135

4 IR8S040

13.260

3.503

5 IR8S050

11.040

2.917

6 IR8S060

7.2400

1.913

8 IR8S080

4.4000

1.162

Weldolet

“H” dimension

part number

inches    mm

CS4W020

2.38      60.45

CS4W025

2.33      59.18

CS4W030

2.32      58.92

CS4W040

2.30      58.42

CS4W050

3.09      78.48

CS4W060

2.96      75.18

CS4W080

2.73      69.34

H-Dimensions 

The plastic insert in Weldolet 

fi

 ttings MUST be removed during the welding process.  When reinstalled, it is important that the insert be 

threaded to the proper height ("H" dimension).

"H"

Weldolet

“H” dimension

part number

inches    mm

CR4W020

2.38      60.45

CR4W025

2.33      59.18

CR4W030

2.32      58.92

CR4W040

2.30      58.42

CR4W050

3.09      78.48

CR4W060

2.96      75.18

CR4W080

2.73      69.34

Содержание 159 001 291

Страница 1: ...ental Requirements Enclosure rating NEMA 4X IP65 Storage Temperature 10 C to 75 C Ambient Temperature 0 C to 65 C Relative Humidity 0 to 90 RH non condensing Altitude 2000 m 6562 ft Pollution Degree 2 Output specifications Signal Averaging Programmable 0 to 100 seconds Sensitivity Response Programmable 0 to 9 scale Pulse divider Total pulse output Pulse Divider Setting 1 0000 to 99999 Maximum puls...

Страница 2: ...allation fittings that control the position of the paddlewheel in relation to the dimensions of the pipe Type Description 2 to 4 inch cut 1 7 16 inch hole in pipe Over 4 inch cut 2 1 8 inch hole in pipe 0 5 to 4 inch versions PVC or CPVC 2 to 4 inch cut 1 7 16 inch hole in pipe 6 to 8 inch cut 2 1 8 inch hole in pipe Iron Carbon Steel 316 SS Threaded tees Carbon steel stainless steel Weld on Weldo...

Страница 3: ...For conduit installations Thread conduit with in NPT threads directly into the conduit port For conduit with ISO threads use the black thread adapter included with the connector kit To comply with NEC requirements do not use any metal conduit in the installation 2537 Paddlewheel Flowmeter for in to 4 in pipe 130 mm 5 12 in 97 mm 3 82 in 2537 Paddlewheel Flowmeter for 5 to 8 in pipe 171 mm 6 73 in ...

Страница 4: ...elay may be a dry contact type or a solid state type The dry contact relay requires an external power source of 24 VDC 10 The solid state relay requires an external power source of 5 to 24 VDC S1 S2 Power Supply 24 VDC 0 03 A Normally Closed Common Normally Open Blk Red Shld Internal sensor connections S1 S2 Power Supply 5 24 VDC 0 03 A No Connection Blk Red Shld 1 2 Load S1 S2 Blk Red Shld t T P ...

Страница 5: ...IZED 0000 0 to 6400 0 page 9 4 Set Set flow RATE to be represented by 4 mA 0 0000 to 99999 page 6 20 Set Set flow RATE to be represented by 20 mA 0 0000 to 99999 page 6 Contrast Adjust visibility of liquid crystal display 1 to 3 page 6 Operation The 2537 Flowmeter is available in 4 different models The programming menus vary significantly from one model to another This chart is provided inside the...

Страница 6: ...rn to Normal Operation Save the new setting Select the volumetric units for the flow measurement Flow Units Example Set the Flow Units to Gallons per minute This function is available on these versions of the 2537 2s 2s T P t T P t T P t T P t 1 2 3 Liters minute Factory setting Liters hour Liters day Liters second Gallons minute Gallons hour Gallons day Gallons second 2s Go to next menu item Retu...

Страница 7: ...nction is set to zero seconds AVERAGING only AVERAGING and SENSITIVITY Averaging and Sensitivity Settings Because ideal flow conditions are often impossible to achieve the flow rate is often erratic which causes any control features ie relays 4 20 mA loops etc that are associated with the flow rate to be erratic The best solution to these problems is to correct any piping deficiency that causes th...

Страница 8: ...heel sensor is divided by the K Factor MULTIPLIED by the P factor The resulting frequency is output through a relay 2s Go to next menu item Return to Normal Operation Save the new setting Select DIVIDER or TOTAL operation The factory setting is TOTAL PULSE DIVIDER Output Input pulses P Factor DIVIDER allows you to set a scaling value P Factor from 1 0000 to 99999 Example If the P Factor is set for...

Страница 9: ...ate reaches the setpoint the 2537 will wait this long in seconds before triggering the alarm The factory setting is 0000 0 seconds 4 Program the DELAY A HI alarm will be activated when the flow rate rises ABOVE the setpoint A LO alarm will be activated when the flow rate falls BELOW the setpoint The factory setting is Hi gh x4 2s 2s T P t T P t t T P 1 2 3 4 1 Select HI or LO Relay Alarm logic 2s ...

Страница 10: ...N COPPER PIPE SCH K 1 2 CUKT005 917 84 242 50 3 4 CUKT007 428 27 113 15 1 CUKT010 256 43 67 749 1 1 4 CUKT012 176 44 46 615 1 1 2 CUKT015 115 69 30 565 2 CUKT020 63 385 16 746 COPPER TEE FITTINGS ON COPPER PIPE SCH L 1 2 CUKT005 858 22 226 74 3 4 CUKT007 385 74 101 91 1 CUKT010 241 64 63 841 1 1 4 CUKT012 170 90 45 152 1 1 2 CUKT015 112 03 29 598 2 CUKT020 61 74 16 310 PIPE SIZE IN FITTING 2536 85...

Страница 11: ... 1 7052 DN 200 SFMT080 4 0720 1 0758 PVC FITTINGS DIN ISO EUROPE ONLY DN 15 PVMT005 972 37 256 90 DN 20 PVMT007 485 69 128 32 DN 25 PVMT010 297 27 78 540 DN 32 PVMT012 170 25 44 980 DN 40 PVMT015 103 71 27 400 DN 50 PVMT020 59 500 15 720 DN 65 PVMT025 34 973 9 2400 DN 80 PVMT030 24 981 6 6000 DN 100 PVMT040 16 275 4 3000 DN 150 PVMT060 8 1756 2 1600 DN 200 PVMT080 4 0878 1 0800 Maintenance and Cle...

Страница 12: ...ulse Divider via Dry Contact Relay Integral Mount 3 2537 2C T0 159 001 316 Pulse Divider via Solid State Relay Integral Mount 3 2537 3C T0 159 001 317 Flow Switch via Dry Contact Relay Integral Mount 3 2537 4C T0 159 001 318 Flow Switch via Solid State Relay Integral Mount 3 2537 5C T0 159 001 319 Digital S3L Integral Mount 3 2537 6C T0 159 001 320 4 20 mA Integral Mount Accessories Mfr Part No Co...

Отзывы: