7-11. Room lamp doesn’t work
Symptom
Check Point
1. Freezer room lamp
doesn’t work
1. Check the freezer door switch sticky
2. Check the door S/W resistance
3. Check the LED Lamp
Resistance [Ω]
Door S/W
No magent near
the switch
Infinity
Magnet is near the
switch
0
*PWM Control Voltage range
CON7
Voltage [V]
9 pin & 11 pin
5.7~12.6V
10 pin & 12 pin
5.7~12.6V
14 pin & 16 pin
5.7~12.6V
*PWM Control Voltage range
LED Lamp
Voltage [V]
White &Yellow
Closed
0~2V
Open
5.7~12.6V
Door S/W
CON7
LED Lamp
1
3
5
7
2
4
6
8
9
11
13
15
17
19
21
23
25
26
10
12
14
16
18
20
22
24
W1 FAN
MACHINE ROOM FAN
HYGIENE LED LIGHT
HYGIENE FAN MOTOR
W1 LED PWM LIGHT
W2 FAN
W3 FAN
YL
GY
BO
RD
BL
PK
RD/YL
YL/BL
WH/BN
PR/WH
BK
BN
PR
WH
WH/RD
BL/RD
SB/BK
BO/WH
BO/BL
YL/BK
WH/BK
BL/WH
W2 LED PWM LIGHT
W3 LED PWM LIGHT