- 18 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE.
All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
(5) L/Piston Trip and LED Blinking 5 times (Locked Piston)
→ Purpose : Detect locked piston.
→ Cause : Oil shortage of the cylinder, Cylinder or Piston damage, clogging the discharge,
Comp. internal debris.
→ Logic : After the Comp. Off every 2 min 30 seconds restart Comp.
Blink Blink
Blink
Blink Blink
OFF
Check
the Protection Logic
Check the L/Piston or
LED blinking 5 times
(Locked Piston
Trip)
Do not operate
Comp.?
Recheck
Reset
Do not operate
Comp.?
N
Y
Replace
Compressor
Clogging the Cycle?
N
Y
Repair
Sealed system