All rights reserved. Only training and service purposes.
3. What to do per LED Blinking and Trip protection logic
(4) Over Voltage Trip and LED Blinking 4 times (Over Voltage Trip)
→ Purpose : Protection the PCB by Over Voltage
→ Cause : Applying the Over Voltage to DC Link(450VDC or higher)
→ Logic: Restart every 90 seconds after compressor off.
Blink
Blink
Blink
Blink Blink
Blink
Blink Blink
OFF
OFF
LED
4 Blinks
Replace PCB
LED
4 Blinks
About 5min
Reset
Test Mode
1 Input