- 70 -
Copyright © 2018-2019 SIGNATURE KITCHEN SUITE.
All rights reserved. Only training and service purposes.
9-2-2. Return of Remained Refrigerant
Required equipment:Pinch pliers,hose for refrigerant recovery,vacuum pump
• If refrigerant return time of 7 minutes has passed,connect a vacuum pump at the ends of a refrigerant return hose outdoor.
(Vacuum pump must operate outdoor.)
• Operate a vacuum pump in order to return refrigerant remained in the pipe.
• Vacuum working time should be for more than 10 minutes.
9-2-3. LokRing Repair Step
• Required equipment: LokRing Tool
• Remove pinch pliers if remaining refrigerant return is completed.
• Cut the front part of a process pipe with a cutter.(Check that remaining refrigerant comes out.)
• Perform LokRing SVC work such as replacement of compressor and dryer,or repair of leakage part.
Содержание SKSCW181RP
Страница 82: ......