97164C (Rev. E - 08/16)
EDFAC11PBC*A EDFBC12PBC*A
Page 1
Installation/Care/Use Manual
SEMI AND FULLY RECESSED WALL
MOUNT CUSPIDOR ONLY
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
FIG. 1
FIG. 2
To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING TH INSTALLATION. CHECK YOUR
INSTALLA-TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER
APPLICABLE CODES. After installation, leave these instructions inside the fountain
for future reference.
SEE FIG. 5
7
SEE FIG. 7
6
INSTALLATION INSTRUCTIONS
1. Remove lower panel from cuspidor by removing the two screws at the lower corners. Rotate the bottom of the panel out and pull
gently downward to remove.
2. Install spreader assembly into cuspidor body and attach straight end of copper tubing as shown in Figure 5. Route the tubing into
the cuspidor compartment and install cuspidor body.
3. Water inlet tube to be 3/8" O.D unplated copper. Waste tailpiece for slip trap is 1-1/4" O.D. Contractor to supply waste trap in
accordance with local codes.
4. Connecting lines to be unplated copper and thoroughly flushed to remove all foreign matter before connection to cuspidor
assembly. The furnished strainer should be installed in the supply line. See Figure 1
DO NOT SOLDER TUBES INSERTED INTO
THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
5. Connect the cuspidor to supply line with shut off valve and install a 3/8" (10mm) water line between the valve and cuspidor.
EDFAC11PBC
EDFBC12PBC
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM
THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS
PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN
FROM THE BUILDING PLUMBING SYSTEM.
IMPORTANT! INSTALLER PLEASE NOTE.
Installer
NOTE: WATER FLOW
DIRECTION
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED COP-
PER TUBE CONNECT
COLD WATER SUPPLY
B
C
A
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A
B
C