background image

97164C (Rev. E - 08/16)

EDFAC11PBC*A  EDFBC12PBC*A

Page 1

Installation/Care/Use Manual

SEMI AND FULLY RECESSED WALL

MOUNT CUSPIDOR ONLY

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

FIG. 1

FIG. 2

To assure you install this model easily and correctly, PLEASE READ THESE 

SIMPLE INSTRUCTIONS BEFORE STARTING TH INSTALLATION. CHECK YOUR 

INSTALLA-TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER 

APPLICABLE CODES. After installation, leave these instructions inside the fountain 

for future reference.

SEE FIG. 5

7

SEE FIG. 7

6

INSTALLATION INSTRUCTIONS

1. Remove lower panel from cuspidor by removing the two screws at the lower corners.  Rotate the bottom of the panel out and pull  

    gently downward to remove.

2. Install spreader assembly into cuspidor body and attach straight end of copper tubing as shown in Figure 5.  Route the tubing into 

    the cuspidor compartment and install cuspidor body.

3. Water inlet tube to be 3/8" O.D unplated copper.  Waste tailpiece for slip trap is 1-1/4" O.D.  Contractor to supply waste trap in 

    accordance with local codes.

4. Connecting lines to be unplated copper and thoroughly flushed to remove all foreign matter before connection to cuspidor   

    assembly. The furnished strainer should be installed in the supply line. See Figure 1 

DO NOT SOLDER TUBES INSERTED INTO  

  THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.

5. Connect the cuspidor to supply line with shut off valve and install a 3/8" (10mm) water line between the valve and cuspidor.

EDFAC11PBC

EDFBC12PBC

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES 

IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM 

THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN 

ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. 

THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS 

PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN 

FROM THE BUILDING PLUMBING SYSTEM.

IMPORTANT!  INSTALLER PLEASE NOTE.

Installer

NOTE: WATER FLOW

            DIRECTION 

BUILDING WATER

            INLET

    SERVICE STOP

(NOT FURNISHED)

1/4" O.D. TUBE

WATER INLET

TO COOLER

3/8" O.D. UNPLATED COP-

PER TUBE CONNECT

COLD WATER SUPPLY

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

Отзывы: