MDP 102-1
29.08.2019
Page 73
7.2.3 Malfunction of the drive
Malfunction of the drive
Cause
Remedy
─
I-FPOS shows decrementing
values when the motor ro-
tates clockwise (view of the
motor shaft)
─ Feedback system is not
connected correctly
─ Connect feedback system according
to drawing
(see page 58)
─
Motor does not rotate
─
Motor current is at the limit
without torque
─ Motor is not connect in cor-
rect orientation
─ Connect motor in correct relation to
terminals
U, V, W
─
The motor casts without set
point
─
The motor torque is too low
or different in the both direc-
tions
─
M-ROFF
is not set to the right
value
─ Motor and/or feedback con-
nection is wrong
─ Set
M-ROFF
to the right value
─ Connect motor and feedback correct-
ly
─
The motor stops in certain
positions
─ The setting of
M-POL
and/ or
M-RPOL
is not correct
─ The motor cable has a broken
wire
─ Not all wires of the motor
cable are connected
─ Set
M-POL
and
M-RPOL
according
to the to the data of the motor
─ Replace motor cable (especially with
drag chains)
─ Connect all wires of the motor cable
─
The motor oscillates
─ Control gain too high
─ Shielding of the feedback
cable has a break
─ Reduce
V-KP
and/or
P-KV
─ Replace feedback cable (especially
with drag chains)
Содержание MDD 111-1
Страница 4: ...MDP 102 1 Page 4 29 08 2019 1 1 Components of a servo system...
Страница 13: ...MDP 102 1 29 08 2019 Page 13 2 6 Nameplate...
Страница 14: ...MDP 102 1 Page 14 29 08 2019 2 7 Block Diagram and Concept Block diagram of the Power Supply Module...
Страница 27: ...MDP 102 1 29 08 2019 Page 27...
Страница 28: ...MDP 102 1 Page 28 29 08 2019 Connector layout of X1 X2 X3 X4 and X6...
Страница 30: ...MDP 102 1 Page 30 29 08 2019 The entire MDD System is grounded over the module carrier in the control cabinet...
Страница 48: ...MDP 102 1 Page 48 29 08 2019...
Страница 50: ...MDP 102 1 Page 50 29 08 2019...
Страница 84: ...MDP 102 1 Page 84 29 08 2019...