![SIGMATEK MDD 111-1 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/sigmatek/mdd-111-1/mdd-111-1_manual_1268140019.webp)
MDP 102-1
29.08.2019
Page 19
2.8 Technical Data Power Supply Module 230 V
DIM
MDP 102-1
Article number
09-403-102-1
Hardware version
3.x
Rated Data
Rated mains voltage (symmetrically to
ground) maximum 5000 rms symmetrical
amps (L1, L2, L3)
V
AC
1 or 3 x 115 V
-10%
/ 1 x 230 V
+10%
,
45 - 65 Hz
Maximum peak current at switch on of the
mains contactor (limited by the inrush
circuit)
A
2
Rated installed power for S1 operation
kVA
2
Rated installed power for S1 operation for
input voltage < 230 V
VA
2 kVA
– 8.7 W * (230 – input voltage/V)
Rated DC-link voltage
V
DC
150 - 360
Over voltage protection threshold of DC-link
voltage
V
DC
450
Auxiliary supply v24 V
V
DC
22 - 30
Maximum leakage current
mA
30
Power of additional supply v24 V
W
Max. 50
Holding brake supply v24 V-BR
V
DC
23 - 26
(depending on type of selected holding brake)
Regen Circuit
DC-Link capacitance
µF
540
G-VMAINS
= 230 (rated mains voltage = 230 V)
Switch-on threshold
V
DC
420
Switch-off level
V
DC
400
Over voltage protection
V
DC
450
Peak power of the internal regen resistor
(max. 1sec)
kW
5.3
Safety Input
Input voltage between ENABLE_H (+) and
ENABLE_L (-)
V
Typically 24, max 30 V
Signal level between ENABLE_H (+) and
ENABLE_L (-)
V
Low ≤ +5, High ≥ +15
Input current
mA
Typically 10 at 24 V
Switching delay times of the inputs
s
Switch-on about 0.02
Switch-off minimum 0.5, maximum 1 s
Relay output (S1, S2)
-
NO
Switching capacity
-
Max. 30 V
DC
, 42 V
AC
, 100µA to 0.5 A
Digital Input
Input voltage Dig_IN1 to Dig_IN8
V
Typically 24, max 30 V
Signal level
V
Low ≤ +5, High ≥ +15
Input current
mA
Typically 10 at 24 V
Switching delay times of the inputs
ms
Typically 0.1
Содержание MDD 111-1
Страница 4: ...MDP 102 1 Page 4 29 08 2019 1 1 Components of a servo system...
Страница 13: ...MDP 102 1 29 08 2019 Page 13 2 6 Nameplate...
Страница 14: ...MDP 102 1 Page 14 29 08 2019 2 7 Block Diagram and Concept Block diagram of the Power Supply Module...
Страница 27: ...MDP 102 1 29 08 2019 Page 27...
Страница 28: ...MDP 102 1 Page 28 29 08 2019 Connector layout of X1 X2 X3 X4 and X6...
Страница 30: ...MDP 102 1 Page 30 29 08 2019 The entire MDD System is grounded over the module carrier in the control cabinet...
Страница 48: ...MDP 102 1 Page 48 29 08 2019...
Страница 50: ...MDP 102 1 Page 50 29 08 2019...
Страница 84: ...MDP 102 1 Page 84 29 08 2019...