ETV 0853-3
CONTROL PANEL
Page 28
12.04.2017
104
C_READY
The CPU is ready for operation.
105
C_OK
The CPU is ready for operation.
106
C_UNKNOWN_CID
An unknown class from a stand-along or
embedded object: unknown base class.
107
C_UNKNOWN_CONSTR
The operating system class cannot be
created; the operating system is probably
wrong.
108
C_UNKNOWN_OBJECT
Reference to an unknown object in an
interpreter program, creation of more
than one DCC080 object.
109
C_UNKNOWN_CHNL
The hardware module number is greater
than 60.
110
C_WRONG_CONNECT
No connection to the required channels.
111
C_WRONG_ATTR
Wrong server attribute.
112
C_SYNTAX_ERROR
No specific error, recompile all and
reload project components.
113
C_NO_FILE_OPEN
An attempt was made to open an un-
known table.
114
C_OUTOF_NEAR
Memory allocation error
115
C_OUT OF_FAR
Memory allocation error
116
C_INCOMAPTIBLE
An object with the same name exists but
has another class.
117
C_COMPATIBLE
An object with the same name and class
exists but must be updated.
224
LINKING
The application is currently linking.
225
LINKING ERROR
An error has occurred while linking. An
error messaged is generated in the
LASAL status window.
226
LINKING DONE
Linking is complete.
230
OP BURN
The operating system is currently being
burned into the Flash memory.
231
OP BURN FAIL
An error has occurred while burning the
operating system.
232
OP INSTALL
The operating system is currently being
installed.
240
USV-WAIT
The power supply was disconnected; the
UPS is active.
The system is shutdown.