Electrical requirements
Supply voltage
Typ24 V DC
M18 V DC
M30 V DC
Current consumption of the
24 V
Typically 350 mA
(with no external devices connected)
Maximum 400 mA
(with external devices connected)
Starting current
Maximum 27 A for 9 µs
The device shall be supplied from an isolating transformer having a secondary listed fuse
rated either:
a) max. 5 amps for voltages 0~20 V (0~28.3 Vp), or
b)
100 VA/Vp for voltages of 20~30 V (28.3~42.4 Vp).
Terminal
Dimensions
220 x 172 x 33.7 mm (W x H x D)
Material
Front plate: 4 mm black anodized aluminum
Weight
Typically 1.1 kg
Environmental conditions
Storage temperature
-10
… +85 °C
Operating temperature
0
… 50 °C
Humidity
10-90 %, uncondensed
EMV stability
EN 61000-6-2: noise resistance
EN 61000-6-4: noise emission
Vibration tolerance
EN 60068-2-6
2-9 Hz: amplitude 3.5 mm
9-200 Hz: 1 g (10 m/s²)
Shock resistance
EN 60068-2-27
150 m/s²
Protection Type
EN 60529
protection through housing
Front: IP65
Cover: IP20