background image

EVENT

PRE-CONDITION

ACTION

LED STATUS

BUZZER STATUS

ACTIVITIES

POST-
CONDITION

FORCE_DATA

Any state

Move Magnet Key
to contact point of
REED SWITCH.
Buzzer beep 1
time, move
Magnet Key away.

Blink SKY BLUE

Beep 1 time

See FW specs

Back to previous
state

PARAMETERS_UPDATE

Any state

Move Magnet Key
to contact point of
REED SWITCH.
Buzzer beep 1
time, hold Magnet
Key 5s.
Buzzer beep 2
times.

Blink PURPLE

Beep 2 times

See FW specs

Back to previous
state

 Whenever the data is sent to base station, the LED will lit with color codes as below:

RC1: 

RED

 colour

RC2: 

GREEN

 colour

RC4: 

BLUE

 colour

NOTE:

Once sending the data to base station by the magnet key, the timer of sending time interval will be reset;

The shortest time interval between the two manual triggers is 15s. if shorter than 15s, there will be no data

sending.

5.1 LED meaning

Содержание WSSFCEX-PPS

Страница 1: ...ANGE 0 10 BARG ACCURACY 0 5 PROCESS CONNECTION 1 2 NPT MALE 316SS TYPE AA BATTERY 1 5VDC RC1 RC6 RC7 ZONES WSSFCEX PPS G 1000 SIGFOX GAGE PROCESS PRESSURE SENSOR ATEX EXD APPROVAL ZONE 1 2 RANGE 0 100...

Страница 2: ...WSSFCEX PPS 1 1 FEB 2022 Update information of WSSFCEX PPS G 1000 WSSFCEX PPS is the Sigfox Integrated Process Pressure Sensor with Exd approval for installation in Zone 1 Zone 2 or Safe Zone and it...

Страница 3: ...dard working time up to 10 years depends on configuration 02 x Battery AA 3 6V is also available as optional ATEX Certificates IMQ 14 ATEX 005 X T V CY 18 ATEX 0206158 X and IECEx DEK 15 0048X Marking...

Страница 4: ...nd the number of times of alarm did not pass the limit of number of alarms then it will send data to Base station immediately 2 When the sending time interval is reached it will send data to Base stat...

Страница 5: ...of REED SWITCH Buzzer beep 1 time hold Magnet Key 5s Buzzer beep 2 times Blink PURPLE Beep 2 times See FW specs Back to previous state Whenever the data is sent to base station the LED will lit with...

Страница 6: ...eRadio Configuration menu Then release to configure it Press to configure After pressing if theBlue LED blinks once it is Radio Configuration 1 After pressing if the Blue LED flashes twice it is Radio...

Страница 7: ...y Frequency hopping The device broadcasts each message 3 times on 3 different frequencies Maximum On time 400 ms per channel No new emission before 20 s Listen Before Talk Devices must verify that the...

Страница 8: ...Step 3 Click New Select a group Step 4 Fill in the required information...

Страница 9: ...ext as shown below Check the box as shown below to register as a prototype Note Some of our products may not have end product certification in time to add the product to Backend Sigfox please follow t...

Страница 10: ...tain time to finish the measurement Once reading the value it can be scaled to any engineering value by the following formula Y aX b Where X the raw value from sensor Y the calculated value will be se...

Страница 11: ...ys 0b111 every 240h 10 days 0b011 every 24h 1 day 3 MEASURE_PERIOD Period of time to measure sensor 0b0000 every 1s 0b0001 every 2s 0b0010 every 5s 0b0011 every 10s 0b0100 every 20s 0b0101 every 30s 0...

Страница 12: ...ARM Alarm 0b00 no alarm 0b01 low alarm 0b10 high alarm 0b11 not used 2 BATTERY_LEVEL Battery level 2 bit unsigned integer 0 3 2 RAW_VALUE Raw value of pressure sensor 12 bit 16 bit unsigned integer 16...

Страница 13: ...SSURE 9 0 bits 4 1 3 2 2 4 16 32 Value 0b0100 4 yes zeros yes yes zeros yes yes ALARM led blink RED Payload EVENT_ID HW_ERROR reserved ALARM BATTERY_LEVEL reserved RAW_VALUE PRESSURE 9 0 bits 4 1 3 2...

Страница 14: ...TYPE 5 Payload PRM_ADDRESS PRM_LENGTH PRM_VALUE reserved DOWNLINK_TYPE 8 0 bits 8 8 16 28 4 Value yes 0x02 2 yes zeros 0b0101 5 Payload PRM_ADDRESS PRM_LENGTH PRM_VALUE reserved DOWNLINK_TYPE 8 0 bits...

Страница 15: ...ttps filerun daviteq com wl id qK0PGNbY1g1fuxTqbFW9SXtEvCw7bpc6 Step 2 Plug the configuration cable to computer viaUSB port and install the driver Step 3 Open the housing Serial port configuration on...

Страница 16: ...Step 4 Plug the connector to the configuration port Red Tx Black Rx Yellow GND Step 5 Insert the battery Tx on cable will go withRx on sensor and vice versa...

Страница 17: ...LE FOR SIGFOX WSSFCEX PPS csv Here is the table of Data will be read by Modbus tool Modbus Register DEC Modbus Register Hex Function Code Read Function Code Write No of Registers Description Range Def...

Страница 18: ...1 2 4 4 uint16 Read Write RC zones selection 1 2 4 is RCZ1 RCZ2 RCZ4 277 115 3 16 1 TX_POWER 20 int16 Read Write RF Tx power 278 116 3 16 2 CONSTANT_A 1 float Read Write Constant a for scaling measure...

Страница 19: ...communicate with Base station but the distance will be reduced significantly 7 Installation 7 1 Locate the good place for Radio signal ATTENTION DO NOT install the Sigfox sensor or its antenna inside...

Страница 20: ...er sensor specification 2 Please make sure the operating temperature and pressure is suitable with the sensor Please refer sensor specification 3 Prepare the professional tools for installation The in...

Страница 21: ...aterials and size must be sizing properly to suit the process conditions It is better to install the isolation valve next to sensor process connector Steps for battery installation Step 1 Turn the fro...

Страница 22: ...AA battery please take note the polarity of battery Step 4 Turn the front cover of the sensor clockwise to close fully ATTENTION REVERSED POLARITY OF BATTERIES IN 10 SECONDS CAN DAMAGE THE SENSOR CIRC...

Страница 23: ...ckages day Check on the base station whether the event message exceeds the number of RF packets 5 Node has sent RF but the LED does not blink LED malfunction LED welding is not good Check LED conditio...

Отзывы: