PARAMETERS_UPDATE
(led blink
PURPLE
)
Payload
EVENT_ID
HW_VERSION
FW_VERSION
LATEST_SIGFOX_
DOWNLINK
10.0
bits
4
4
8
64
Value
0b0010 = 2
yes
yes
yes
FORCE_DATA
(led blink
SKY
BLUE
)
Payload
EVENT_ID
HW_ERROR
reserved
ALARM
BATTERY_LEVEL
reserved
RAW_VALUE PRESSURE
8.0
bits
4
1
3
2
2
4
16
32
Value
0b0011 = 3
yes
zeros
yes
yes
zeros
yes
yes
CYCLIC_DATA
(led blink
SKY
BLUE
)
Payload
EVENT_ID
HW_ERROR
reserved
ALARM
BATTERY_LEVEL
reserved
RAW_VALUE PRESSURE
9.0
bits
4
1
3
2
2
4
16
32
Value
0b0100 = 4
yes
zeros
yes
yes
zeros
yes
yes
ALARM
(led blink
RED
)
Payload
EVENT_ID
HW_ERROR
reserved
ALARM
BATTERY_LEVEL
reserved
RAW_VALUE PRESSURE
9.0
bits
4
1
3
2
2
4
16
32
Value
0b0101 = 5
yes
zeros
yes
yes
zeros
yes
yes
User can set the down link data in Sigfox back-end system in advance, whenever the Sigfox node connected to base
stations and with downlink waiting is enable at that time (one time in 6 hours), the downlink data will be loaded to
5.7.3 Payload for Downlink, length is 8 bytes.
The Sigfox node is only able to receive max 04 downlinks a day, each downlink will be waiting in every 06 hours.