Sigfox node.
The downlink data can be any configuration parameter.
Size
DOWNLINK_TYPE = 0
Payload
HIGH_ALARM_SETPOINT
LOW_ALARM_SETPOINT_FACTOR
ALARM_ENABLE
ALARM_PERIOD
LED_BUZZER_ENABLE
HEARTBEAT_PERIOD
8.0
bits
32
8
1
3
1
3
Value
yes
yes
yes
yes
yes
yes
MEASURE_PERIOD
TX_REPEAT
CYCLIC_DATA_PERIOD
DEVICE_RESET
DOWNLINK_TYPE
4
1
3
4
4
yes
yes
yes
yes
0b0000 = 0
Size
DOWNLINK_TYPE = 5
Payload
PRM_ADDRESS
PRM_LENGTH
PRM_VALUE
reserved
DOWNLINK_TYPE
8.0
bits
8
8
16
28
4
Value
yes
0x02 = 2
yes
zeros
0b0101 = 5
Payload
PRM_ADDRESS
PRM_LENGTH
PRM_VALUE
reserved
DOWNLINK_TYPE
8.0
bits
8
8
32
12
4
Value
yes
0x04 = 4
yes
zeros
0b0101 = 5
Please pay attention when send downlink data. If there was a mistake in sending wrong data, it would
cause the Sigfox node not working properly and user need to configure it by offline cable!!!
6. Configuration
DANGER:
DO NOT OPEN THE COVER AT HAZARDOUS LOCATION!
ONLY OPEN COVER FOR TROUBLE SHOOTING AND CONFIGURATION IN SAFE AREA!