Here is the table for Configuration:
Modbus
Register
(DEC)
Modbus
Register
(Hex)
Function
Code
(Read)
Function
Code
(Write)
No. of
Registers
Description
Range
Default
Format
Property
Comment
270
10E
3
16
4
CURRENT_CONFIGURATION
hex
Read/Write
274
112
3
16
1
SERVER_CONFIG
uint16
Read/Write
0: Send to
Sigfox
Network
1: Send to
Dongle
276
114
3
16
1
RADIO_CONFIG
1, 2, 4
4
uint16
Read/Write
RC zones
selection
1, 2 ,4 is
RCZ1,
RCZ2,
RCZ4
277
115
3
16
1
TX_POWER
20
int16
Read/Write
RF Tx
power
278
116
3
16
2
CONSTANT_A
1
float
Read/Write
Constant a
for scaling
measured
value
280
118
3
16
2
CONSTANT_B
0
float
Read/Write
Constant b
for scaling
measured
value
282
11A
3
16
2
HIGH_CUT
1000000000
float
Read/Write
High cut
value for
calculated
value
284
11C
3
16
2
LOW_CUT
-
1000000000 float
Read/Write
Low cut
value for
calculated
value
286
11E
3
16
2
SENSOR_BOOT_TIME
200
uint32
Read/Write
Boot time
of
sensor/input,
in ms