Saving and compiling with SIMOTION SCOUT/SCOUT TIA
1. Save and compile the project, e.g. via the Project -> Save and recompile changes menu.
2. You can select the "Check consistency" option in the Project menu of the main SIMOTION
SCOUT/SCOUT TIA menu at any time. (For more information, refer to the SCOUT online
help.) In this way, you can check whether the configuration, parameterization and
programming in SIMOTION SCOUT/SCOUT TIA matches the defined hardware
configuration.
3. Transfer the project to the controller.
3.6
Notes for those changing over
When changing over from the TM15/TM17 High Feature Terminal Modules to the TM Timer
DIDQ technology modules, the following points must be worked through:
● Modifications must be made in the control cabinet and interconnections adapted.
● The project must be adapted analogously to the procedure described in Chapter
Configuring.
● PROFINET communication with isochronous mode must be configured.
Note
The connection to the SIMOTION hardware cannot be realized using DRIVE-CLiQ as is the
case for TM15/TM17 High Feature; PROFINET must always be used.
Configuring
3.6 Notes for those changing over
Technology Modules TM Timer DIDQ for SIMOTION SCOUT and SIMOTION SCOUT TIA
Commissioning Manual, 01/2015