![Siemens TM Timer DIDQ Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/siemens/tm-timer-didq/tm-timer-didq_commissioning-manual_1265510037.webp)
Further information
Further information on configuring the output cam and measuring input technology objects can
be found in the
SIMOTION Motion Control Output Cams and Measuring Inputs Function
Manual.
See also
Service and maintenance (Page 65)
3.2.5.3
Linking symbolic I/O variables with TM Timer DIDQ
You can address digital I/O channels using symbolic variables in the user program.
Precondition
The I/O channels are configured as described under Chapter Configuring I/O channels
Procedure
In the following example, create variable 'var_QI_MI' and link this with quality information QI
of the measuring input input MI_0.
1. Open the address list via the project navigator.
2. In the View field, select 'I/Os'.
3. Create the variable 'var_QI_MI', type "BOOL", and select 'IN' in the I/O address field.
Figure 3-13 Creating variables in the address list
4. In the Assignment field, click on
Configuring
3.2 SIMOTION SCOUT
Technology Modules TM Timer DIDQ for SIMOTION SCOUT and SIMOTION SCOUT TIA
Commissioning Manual, 01/2015
37