Parameters
Value range
Default
Level selection for HW enable
● Active at high level
● Active at low level
Active at high level
Configuration DQ/DI group
(DQ2/DI2/DI3)
● Incremental encoder (A, B phase
shift)
● Timer DI2 with enable input DI3
● Timer DQ2 with enable input DI2
● Use inputs individually
Incremental encoder (A, B
phase shift)
Invert counting direction
(incremental encoder)
● Deactivated
● Activated
Deactivated
Operating mode of the digital output
● Numerator
● Timer DI
● Oversampling
Timer DI
Input delay for the
digital input
● none
● 0.05 ms
● 0.1 ms
● 0.4 ms
● 0.8 ms
0.1 ms
Signal evaluation for the counter
● With rising edge
● With falling edge
With rising edge