![Siemens ST950 Скачать руководство пользователя страница 95](http://html.mh-extra.com/html/siemens/st950/st950_user-manual_1265504095.webp)
ST950 Plus+ User Manual
ST950 Plus+ User Manual
Page 95 of 176
667/HE/53000/000
Issue 2
Unrestricted
Cable
Core
Function
Orange
D+ (downstream)
White
D- (downstream)
Green
Earth (for terminating armouring)
Table 15 : Smartloop Interface Detail
Figure 54: 'Torpedo' Resin Joint
4.9.1
Installing Smartloop
The Smartloop device is normally installed in access chambers that are located near to the location
where the inductive loops are to be cut.
Smartloop Installation Location
Instructions for the installation location of the Smartloop(s) is found in the issued STS drawing,
as generated by the Plus+ design tool.
The two cables that are attached to the Smartloop box are the Plus+ network cable and the loop
feeder/tails cable.
Loop feeder/tails are connected, using torpedo resin joints or other appropriate cable connection
methods, as per the Table 15.