![Siemens ST950 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/siemens/st950/st950_user-manual_1265504023.webp)
ST950 Plus+ User Manual
ST950 Plus+ User Manual
Page 23 of 176
667/HE/53000/000
Issue 2
Unrestricted
Figure 9 : Smartloop Layout Example 4 : MOVA
Configuration
One of the fundamental changes, that has been brought about by Plus
+
, is that there no longer is
a 1:1 link between outputs from a controller lamp switch card and the individual aspects. This link
is now achieved out on-street, between the Node and the aspect, push button or pedestrian
display unit.
In order to
‘link’ the functional design (IC4) and the on
-street equipment a new layer of
configuration is required. It is known as the Plus
+
Design Layout Configuration.
For Plus
+
, the IC4 configuration is fundamentally unchanged, where the traffic junction
configuration (operation) is defined, terms of streams, phases, lamp monitoring and detector
inputs.
The Plus
+
Design Layout Configuration now provides the link between the IC4 configuration and
the junction layout as designed
–
as opposed to wiring in a Lamp Switch Card.
Siemens Mobility has developed the Plus
+
Design Layout Tool, which works hand in hand with
KeySignals (KeySoft product). KeySignals provides a toolset for Traffic Engineers to design their
junctions within the AutoCAD product suit.
Plus+ Street Cable
from RAG Node
Torpedo
joint
Loop Feeder
2
2
2
2
4
45m
100m
S
L
SmartLoop
Plus+ Loops
X
IN
S
L
X
IN
2
2
2
Torpedo
joint
Torpedo
joint
Torpedo
joint
SmartLoop
Plus+ Loops
Plus+ Street Cable from
Upstream Smartloop
4