PROGRAMMING
7-4
SIG-QG-21-01
NOVEMBER 2021
Version: A
Trouble
Cause
Action
Correction
Gate drops too
quickly
Incorrect
counterweight
settings
Verify correct
counterweighting.
Adjust as necessary to achieve
proper horizontal and vertical torque
values
Gate Descent time
is not set to the
desired speed.
Verify gate descent time
is programmed a lower
value than intended.
Refer to the programming section of
this manual and reprogram the Gate
descent time to the desired fall time.
Gate raises
partially then falls
Motor overload is
tripped
Determine if yellow Motor
Overload LED is
illuminating during
operation.
Clear gate of any obstructions and
ensure the drive train rotates freely.
Verify correct
counterweighting.
Adjust as necessary to achieve
proper horizontal and vertical torque
values.
Low battery voltage
Verify battery voltage is
dropping below the 11
VDC minimum during
operation.
Ensure a minimum of 11 VDC is
sustained at all times on terminals
B12 and N12 while the gate is
ascending.
Gate arm does not
rise to the desired
vertical position
Gate Up position
improperly
programmed.
Verify Gate Up position is
not programmed to the
desired vertical angle
(position).
Refer to the programming section of
this manual and reprogram the Gate
Up position to the desired vertical
angle as defined by the site-specific
conditions. (*Note- the Gate Up
position can only be set to a vertical
angle ranging from 70 to 88
degrees).
Gate arm rests
above or below
the desired
horizontal position
Incorrect horizontal
buffer setting
Check the horizontal
buffer setting.
Adjust the horizontal buffer so the
gate arm is resting in the level
position and the gate arm height is
properly set in reference to the
crown of the roadway.
It may be necessary to raise or
lower the mechanism on the mast to
achieve the proper gate height
above the roadway and to ensure
the gate arm is level.
Digital Contacts
not operating as
intended
Contact
Open/Closed in the
horizontal position
functionality is
reversed.
Verify contact
programming setting.
In the programming sequence
toggle from the Open in the
Horizontal position to Closed in the
Horizontal position (or vice versa)
state for the respective contact.
Содержание SMART GATE S-80
Страница 44: ...PROGRAMMING 5 6 SIG QG 21 01 NOVEMBER 2021 Version A This Page Intentionally Left Blank ...
Страница 52: ...PROGRAMMING 7 6 SIG QG 21 01 NOVEMBER 2021 Version A This Page Intentionally Left Blank ...
Страница 54: ...HARDWARE TORQUE GUIDELINES 8 2 SIG QG 21 01 NOVEMBER 2021 Version A This Page Intentionally Left Blank ...